1999
DOI: 10.1016/s0009-2509(98)00539-9
|View full text |Cite
|
Sign up to set email alerts
|

Determination of binary competitive equilibrium isotherms from the individual chromatographic band profiles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
37
0
4

Year Published

2009
2009
2020
2020

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 93 publications
(41 citation statements)
references
References 21 publications
0
37
0
4
Order By: Relevance
“…The process parameters for Varicol (feed, eluent, raffinate, extract and recycling flow rates) were calculated by HELP 10.3 software from NOVASEP®, which is based on a competitive Langmuir model modified to include a correction term for solution concentration (James et al, 1999).…”
Section: Overload Experiments and Software Simulationmentioning
confidence: 99%
See 1 more Smart Citation
“…The process parameters for Varicol (feed, eluent, raffinate, extract and recycling flow rates) were calculated by HELP 10.3 software from NOVASEP®, which is based on a competitive Langmuir model modified to include a correction term for solution concentration (James et al, 1999).…”
Section: Overload Experiments and Software Simulationmentioning
confidence: 99%
“…The injection of different volumes provided overload chromatograms ( Figure 5) that allowed the evaluation of the interactions between the enantiomers and the chiral stationary phase. After determining the chromatographic parameters and the overloaded elution profiles for the enantiomeric mixtures of verapamil, it was possible to calculate the operating parameters (feed, eluent, raffinate, extract and recycle stream flow rates), column distribution and overall switching time of the streams used in the Varicol system using the program HELP® 10.3, which is based on a competitive Langmuir model modified to include a correction term for the solution concentration (Seidel-Morgenstern, 2004;James et al, 1999). The operating parameters are shown in Table 2.…”
Section: Operating Conditions For the Varicol Systemmentioning
confidence: 99%
“…The retention times of five overloaded chromatograms were inserted into the software HELP® which is based on the competitive Langmuir model adapted to include a correction term for solution concentration according to the procedure described by [15]. The general form of the isotherm equation is as follows:…”
Section: Chromatographic Parameters and Nonlinear Isothermmentioning
confidence: 99%
“…Isotherm plots generally deviate from linear behavior for various reasons, mainly related to the saturation and/or heterogeneity of the surface or to adsorbate-adsorbate interactions in the bulk fluid and/or close to the surface [15]. The consequences of the nonlinear behavior for the profiles of www.cet-journal.com chromatographic bands are well known.…”
Section: Adsorption Isothermsmentioning
confidence: 99%
“…Yu et al [16] and Ziyang et al [17] have estimated adsorption equilibrium constants and kinetic parameters using GA. James et al [18] estimated adsorption isotherms coefficients with the conjugate gradient method, and Zhang et al [19] used a variation of GA for the same purpose.…”
Section: Introductionmentioning
confidence: 99%