1987
DOI: 10.1039/ja9870200455
|View full text |Cite
|
Sign up to set email alerts
|

Determination of cadmium, copper, manganese and rubidium in plastic materials by graphite furnace atomic absorption spectrometry using solid sampling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

1990
1990
2006
2006

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…The necessity of (time-consuming) digestion and the inherent chance of contamination are, however, major disadvantages. Time-saving solid sampling techniques have, therefore, also been used for the analysis of polymers: destructive techniques like graphite furnace AAS 10 and laser ablation ICPOES 5 and ICPMS 11 and nondestructive ones like instrumental neutron activation (INAA) 8 and X-ray fluorescence (XRF). 8 Of all these techniques, XRF is mostly used as a routine tool for production control because of its ability to provide fast and semiquantitative results.…”
mentioning
confidence: 99%
“…The necessity of (time-consuming) digestion and the inherent chance of contamination are, however, major disadvantages. Time-saving solid sampling techniques have, therefore, also been used for the analysis of polymers: destructive techniques like graphite furnace AAS 10 and laser ablation ICPOES 5 and ICPMS 11 and nondestructive ones like instrumental neutron activation (INAA) 8 and X-ray fluorescence (XRF). 8 Of all these techniques, XRF is mostly used as a routine tool for production control because of its ability to provide fast and semiquantitative results.…”
mentioning
confidence: 99%
“…graphite furnace is used. These fairly recent references typically report data based on calibration against aqueous standards (11)(12)(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25). Table I highlights the suitability of this approach for the successful determination of many elements in a wide variety of sample matrices.…”
Section: Potential Problemsmentioning
confidence: 99%
“…Another approach is the direct analysis of solid samples assayed by graphite furnace atomic absorption spectrometry with a solid sampling device [13][14][15] by Xray fluorescence 16 or by laser ablation ICP-MS. 17 However, solid sampling presupposes the availability of solid standards for the construction of calibration graphs. The use of organic solvents to dissolve plastics is not applicable for sparingly soluble polymers.…”
Section: Introductionmentioning
confidence: 99%