2012
DOI: 10.1016/j.aca.2011.11.025
|View full text |Cite
|
Sign up to set email alerts
|

Determination of chlorophenols in landfill leachate using headspace sampling with ionic liquid-coated solid-phase microextraction fibers combined with gas chromatography–mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
22
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 51 publications
(22 citation statements)
references
References 44 publications
0
22
0
Order By: Relevance
“…They include poly(3,4-ethylene dioxythiophene) [146] and a sol-gel based amino fiber [351] for analysis of pesticides. Polyaniline [88,147], oxidized multiwalled carbon nanotubes [138], and 1-butyl-3-methylimidazolium hexafluorophosphate [124] have been applied to the analysis of phenols. Furthermore, a nanofiber coated by electrospun PU [370] was utilized for analysis of chlorobenzene.…”
Section: Aqueous Samplesmentioning
confidence: 99%
“…They include poly(3,4-ethylene dioxythiophene) [146] and a sol-gel based amino fiber [351] for analysis of pesticides. Polyaniline [88,147], oxidized multiwalled carbon nanotubes [138], and 1-butyl-3-methylimidazolium hexafluorophosphate [124] have been applied to the analysis of phenols. Furthermore, a nanofiber coated by electrospun PU [370] was utilized for analysis of chlorobenzene.…”
Section: Aqueous Samplesmentioning
confidence: 99%
“…Cui et al [39] also found etched SSWs could load more IL than non-etched SSWs. Even though Ho et al [40] demonstrated their IL coating prepared on untreated fused-silica fiber with the dipping method could stand no less than eight extraction-desorption circles, these IL coatings were not stable enough, recoating was required during uses [36][37][38][39][40]. The first relatively long-term reusable IL-based SPME fiber was prepared by fixing IL-impregnated silicone elastomer on a bare fused-silica fiber [41], followed by Carda-Broch et al [42] and Wanigasekara et al [43] who glued IL-functionalized silica particles on fused-silica fibers, which loaded more IL on the fiber as well.…”
Section: Ils and Pilsmentioning
confidence: 96%
“…This method can also be used in the headspace mode to overcome problems related to the stability and solubility of the extraction solvent. Ho et al [63] exploited the advantages of SPME, reused the spent SPME fiber and coated it with an IL solution film. A great advantage of these methods is also that the extraction solvents can be easily and rapidly changed according to the requirements of the analysis.…”
Section: Solvent Supported Microextractionmentioning
confidence: 99%