2010
DOI: 10.1016/j.enconman.2010.02.016
|View full text |Cite
|
Sign up to set email alerts
|

Determination of frequency stability border of power system to set the thresholds of under frequency load shedding relays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(8 citation statements)
references
References 10 publications
0
8
0
Order By: Relevance
“…Due to its simplicity and accuracy, for simulation studies, we have used this model with the typical parameters given in Table 2 (Chang-Chien et al, 2012). Details regarding the SFR model have been presented in (Aik, 2006;Amjady & Fallahi, 2010). It should be mentioned that the aim of the proposed load shedding scheme is to maintain the minimum frequency (f min ) and the steady state frequency (f ss ) above 58.4 and 59.2 Hz, respectively.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…Due to its simplicity and accuracy, for simulation studies, we have used this model with the typical parameters given in Table 2 (Chang-Chien et al, 2012). Details regarding the SFR model have been presented in (Aik, 2006;Amjady & Fallahi, 2010). It should be mentioned that the aim of the proposed load shedding scheme is to maintain the minimum frequency (f min ) and the steady state frequency (f ss ) above 58.4 and 59.2 Hz, respectively.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…The contribution of VI control combined with conventional control is studied under several test cases (i.e. cases [11][12][13][14][15][16][17][18] for the two test systems. Like DR control, the impacts of VI control on the sensitivity and stability of SFR depend upon the parameters of the CL systems.…”
Section: Controlmentioning
confidence: 99%
“…In the conventional power system, frequency regulation is achieved through spinning and non-spinning reserves during normal conditions and underfrequency load shedding (UFLS) is employed under contingency conditions to avoid larger black-outs. In [11], an analytical generalorder SFR model is developed which incorporates load shedding while in [12], an analytical approach is presented to determine the frequency stability border of the power system to set the thresholds of UFLS relays. Similarly, UFLS schemes based on classical control [13] and adaptive methods [14,15] are also proposed.…”
Section: Introductionmentioning
confidence: 99%
“…Frequency stability is the ability of the system to remain at a constant frequency, even if there is an imbalance between the load and generation in case the power system is exposed to a disturbance (Amjady & Fallahi, 2010). Deactivation of one or more of the synchronous machines or loads in the power system or the activation of a new energy source is caused to change in the system frequency.…”
Section: Introductionmentioning
confidence: 99%