2004
DOI: 10.1016/j.chroma.2004.01.046
|View full text |Cite
|
Sign up to set email alerts
|

Determination of fuel dialkyl ethers and BTEX in water using headspace solid-phase microextraction and gas chromatography–flame ionization detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
39
0
4

Year Published

2006
2006
2015
2015

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 114 publications
(44 citation statements)
references
References 28 publications
1
39
0
4
Order By: Relevance
“…Each assay consisted of about 1.0 g of adsorbent for every 100 ml organic solution placed in closed glass vials and immersed in a thermostatic bath. Kinetic mathematical model of pseudo-second order in the linear form was used to correlate the experimental data obtained using Equation (1).…”
Section: Kinetics and Balance Adsorption Of Benzene And Toluenementioning
confidence: 99%
“…Each assay consisted of about 1.0 g of adsorbent for every 100 ml organic solution placed in closed glass vials and immersed in a thermostatic bath. Kinetic mathematical model of pseudo-second order in the linear form was used to correlate the experimental data obtained using Equation (1).…”
Section: Kinetics and Balance Adsorption Of Benzene And Toluenementioning
confidence: 99%
“…Contamination of the aquatic environment is well documented for MTBE, but less for TAME and ETBE. In the 1990s MTBE was reported in groundwater and surface waters with increasing frequency, initially in the USA (Squillace et al, 1996;Happel et al, 1998;Johnson et al, 2000) and thereafter also in Europe (Achten et al, 2002;Klinger et al, 2002;Morgenstern Rosell et al, 2003Rosell et al, , 2006Arambarri et al, 2004;Kolb and Puttmann, 2006a,b). Tap water from various regions (USA, Germany and The Netherlands) was found to contain generally low (ng L À1 ) levels of MTBE (Deeb et al, 2003;Morgenstern et al, 2003;Kolb and Puttmann, 2006b;Cardinali et al, 2008).…”
Section: Introductionmentioning
confidence: 99%
“…Another advantage of headspace is that there is frequently an important decrease in extraction time relative to direct immersion of the fiber. 24 In exposed workers the use of a carboxen-PDMS fiber for toluene extraction allowed for the detection of the unaltered solvent using GC-FID in all samples; PDMS extraction permitted detection in only three of these. The absorption of toluene by the workers was probably low, as supported by urinary hippuric acid levels found.…”
Section: Resultsmentioning
confidence: 99%