2011
DOI: 10.1080/10826076.2011.591022
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Landiolol in Human Plasma by High-Performance Liquid Chromatography With Fluorescence Detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2012
2012
2025
2025

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…Midodrine is also used for the treatment of hypotension related to dialysis, orthostatic hypotension, and desautonomia. [1][2][3][4][5] To date, many analytical methods have been reported for estimating the above-mentioned drug, including chromatographic, [6][7][8][9][10][11][12][13][14][15] spectrouorimetric, [16][17][18][19] spectrophotometric, [20][21][22] and electrochemical methods. [23][24][25] However, the conventional methods employed for the quantication of midodrine hydrochloride, such as high-performance liquid chromatography (HPLC), oen suffer from several limitations, such as time-consuming sample preparation and the use of expensive and highly pure organic solvents, while ultraviolet-visible (UV-vis) spectroscopy has low sensitivity and possible interference from excipients present in the formulation.…”
Section: Introductionmentioning
confidence: 99%
“…Midodrine is also used for the treatment of hypotension related to dialysis, orthostatic hypotension, and desautonomia. [1][2][3][4][5] To date, many analytical methods have been reported for estimating the above-mentioned drug, including chromatographic, [6][7][8][9][10][11][12][13][14][15] spectrouorimetric, [16][17][18][19] spectrophotometric, [20][21][22] and electrochemical methods. [23][24][25] However, the conventional methods employed for the quantication of midodrine hydrochloride, such as high-performance liquid chromatography (HPLC), oen suffer from several limitations, such as time-consuming sample preparation and the use of expensive and highly pure organic solvents, while ultraviolet-visible (UV-vis) spectroscopy has low sensitivity and possible interference from excipients present in the formulation.…”
Section: Introductionmentioning
confidence: 99%
“…The supernatant was aliquoted to polyethylene tubes after centrifugation at 3,000 rpm for 5 min and stored at -20°C until assay. Landiolol in human plasma was stable at -20°C for at least 3 weeks, 29) and all samples were measured within 3 weeks after collection.…”
Section: Assessment Of Hepatic Blood Flowmentioning
confidence: 99%
“…Measurement of Landiolol by HPLC The concentration of landiolol was measured by HPLC with a method that we previously established 29) with minor modifications for physostigmine sulfate (2.0 mol/L). Propranolol hydrochloride solution (20 µg/mL, 5 µL) as an internal standard and 1.0 mL of ethyl acetate were added to 105 µL plasma, which was adjusted to pH 9.0 with 4.0 µL of 0.5 mol/L NaOH.…”
Section: Calculation Of Half-life Of Landiolol In Human Bloodmentioning
confidence: 99%