2018
DOI: 10.1016/j.sab.2017.12.002
|View full text |Cite
|
Sign up to set email alerts
|

Determination of lead in flour samples directly by solid sampling high resolution continuum source graphite furnace atomic absorption spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 24 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…Because of health concerns, detection and determination of lead in water and food samples become very important. The most commonly analytical methods for lead detection are inductively coupled plasma mass spectrometry (ICP‐MS) , atomic absorption spectrometry (AAS) . However, these techniques require expensive, sophisticated instruments and labors and high operation costs, which are not suitable for routine in‐field monitoring of samples.…”
Section: Introductionmentioning
confidence: 99%
“…Because of health concerns, detection and determination of lead in water and food samples become very important. The most commonly analytical methods for lead detection are inductively coupled plasma mass spectrometry (ICP‐MS) , atomic absorption spectrometry (AAS) . However, these techniques require expensive, sophisticated instruments and labors and high operation costs, which are not suitable for routine in‐field monitoring of samples.…”
Section: Introductionmentioning
confidence: 99%
“…The instrumental LODs and LOQs values for Ni and Pb were similar to those previously reported for these elements using HR-CS GFAAS. 23,[25][26][27] For the secondary lines used for Fe and Mn determination, for comparison, we did not nd literature data using only the CP or the side pixel registration approach as the analytical signal. The sensitivity, LODs and LOQs of these elements could be improved, if necessary, to analyse samples with a lower content of Fe or Mn using CP ± 1 and/or a more sensitive analytical line for the The relative LOD values for Pb, Ni, Mn, and Fe were 0.50 mg g −1 , 1.1 mg g −1 , 0.50 mg g −1 , and 0.030 mg g −1 , respectively.…”
Section: Calibration and Gures Of Meritmentioning
confidence: 99%
“…10 Hence, the development of novel, rapid, and robust techniques to precisely and accurately quantify the level of Pb in environmental and biological samples is of the greatest importance. 3 To determine the level of Pb in different matrixes, various analytical methods have been utilized, including electrochemistry, 11 inductively coupled plasma mass spectrometry (ICPMS), 12 inductively coupled plasma optical emission spectrometry (ICPOES), 13 hydride generation atomic fluorescence spectrometry (HGAFS), 14 graphite furnace atomic absorption spectrometry (GFAAS), 15 and hydride generation atomic absorption spectrometry (HGAAS). 16 Among these methods, GFAAS and ICPMS are the most commonly used in laboratories.…”
Section: Introductionmentioning