Determination of lead in foodstuffs and biological samples by hydride generation atomic absorption spectrometry using an aqueous slurry technique

Abstract: A simple and rapid method is described for the determination of lead in foodstuffs and biological samples which corn bines a slurry procedure with lead hydride generation atomic absorption spectrometry (HGAAS). The powdered samples are suspended in Triton X-100 and shaken with 10.0 g of blown zirconia spheres until a slurry is formed. The determination of lead in slurries was carried out by HGAAS in an ammonium persulphatenitric acid medium. Several aspects were studied: the addition of an antifoaming agent; e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

1991
1991
2007
2007

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(10 citation statements)
references
References 0 publications
0
10
0
Order By: Relevance
“…Moreover, larger samples required the addition to the slurry of higher volumes of Triton X-100, and sample sizes below 0.7 g were not representative of the real sample and yielded inaccurate values in Pb and Cd determinations. The addition of a thixotropic thickening agent is necessary to produce a suspension that remains stable for several days and that can be sampled reproducibly (Madrid et al, 1989). In our experiments, Triton X-100 was used as a dispersing agent.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, larger samples required the addition to the slurry of higher volumes of Triton X-100, and sample sizes below 0.7 g were not representative of the real sample and yielded inaccurate values in Pb and Cd determinations. The addition of a thixotropic thickening agent is necessary to produce a suspension that remains stable for several days and that can be sampled reproducibly (Madrid et al, 1989). In our experiments, Triton X-100 was used as a dispersing agent.…”
Section: Resultsmentioning
confidence: 99%
“…A few drops of 30% (v/v) silicone antifoaming emulsion in water was added before slurry dilution with deionized Milli-Q water. This grinding procedure ensured that 90% of the particles had a diameter of less than 25 pm (Madrid et al, 1989). This particle size was small enough to determine Pb and Cd by…”
Section: Methodsmentioning
confidence: 99%
“…As has been reported in the literature, an improved limit of detection for lead by hydride generation and atomic spectroscopic detection can be obtained by including an auxiliary oxidizing agent such as persulphate [5,7,12]. The dashed line in Fig.…”
Section: Resultsmentioning
confidence: 87%
“…The method has been applied to the determination of lead, but difficulties due to low efficiency of the plumbane generation have been reported [2]. However, this could be improved by addition of an oxidizing agent and a number of reagent systems have been proposed [3][4][5][6][7][8][9]. A recent review by Madrid and Ca´mara gives an overview of the topic [10].…”
Section: Introductionmentioning
confidence: 99%
“…A variety of sample pre-treatment procedures and additives [12][13][14][15][16][17][18] have been described and evaluated for the production of quasi-stable suspensions of samples prior to analysis by atomic spectrometry. Alternatively, suspensions with a tendency to segment rapidly have been reproducibly sampled by using ultrasonic agitation, 19 air or argon 20 bubbling, vortex mixing 21 or magnetic stirring.…”
mentioning
confidence: 99%