2016
DOI: 10.1080/00032719.2016.1172232
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Lysozyme by Graphene Oxide–Polyethylene Glycol-Based Fluorescence Resonance Energy Transfer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 42 publications
0
5
0
Order By: Relevance
“…However, the hydrogel H1 without the aptamers showed a significantly high LoD of 37.2 μM ( Figure S4 ) compared with the DNA−H1−960, further demonstrating the decisive rule of the aptamer in this sensing platform. Additionally, the lysozyme detection based on photonic hydrogel DNA−H1−960 provided an excellent LoD compared with other detection method ( Table S2 ) [ 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 ]. The results demonstrated that the constructed DNA−H1−960 can be a sensitive aptasensor for the detection of lysozyme.…”
Section: Resultsmentioning
confidence: 97%
“…However, the hydrogel H1 without the aptamers showed a significantly high LoD of 37.2 μM ( Figure S4 ) compared with the DNA−H1−960, further demonstrating the decisive rule of the aptamer in this sensing platform. Additionally, the lysozyme detection based on photonic hydrogel DNA−H1−960 provided an excellent LoD compared with other detection method ( Table S2 ) [ 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 ]. The results demonstrated that the constructed DNA−H1−960 can be a sensitive aptasensor for the detection of lysozyme.…”
Section: Resultsmentioning
confidence: 97%
“…GO is known to present two main SERS bands located at 1351 cm −1 and 1590 cm −1 corresponding to the D and G bands, respectively. The D band represents disordered sp3 carbon while the G band is associated with the stretching mode of ordered sp2 crystalline graphite-like structures [22]. The spectra of Figure 6b were tentatively normalized to the G band of GO at 1580 cm −1 but the analysis of the normalized spectra provided substantially the same results.…”
Section: Calibration Curve For Fibrillar Hwl On Go-agnc/nsmentioning
confidence: 89%
“…More recently, Pereira-Barros et al proposed an aptamer-based Surface Plasmon Resonance method to selectively detect lysozyme concentrations as low as 0.5 µmol/L [20,21]. Lower detection limits were obtained using more complex procedures involving Fluorescence Energy Transfer [22], luminescent G-quadruplex Iridium(III) complexes [23], field-effect transistor (FET)-based sensing [24], and fluorescent biosensor coupled with gold nanoparticles [25,26]. On the other hand, studies on the detection of the fibrillar form of lysozyme are only in their infancy.…”
Section: Introductionmentioning
confidence: 99%
“…This process introduces reactive oxygen-based functional groups, including hydroxy, carboxyl, epoxide, and carbonyl groups, onto the basal planes and borders of the graphene-derived layers, increasing the distance between layers [31,32]. In particular, it has been widely noted that these reactive functional groups are helpful when synthesizing GO-based composite materials, such as the synthesis of RGO-Fe 3 O 4 composite [33], graphene oxide/polyethylene glycol composite [34], Cellulose-Graphite Oxide Composite [35], and so on.…”
Section: Introductionmentioning
confidence: 99%