2009
DOI: 10.1002/elan.200804377
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Manganese in Natural Media by Anodic Stripping Voltammetry Using a Rotating Solid Silver Amalgam Electrode

Abstract: Detection of Mn(II) using differential pulse anodic stripping voltammetry (DPASV) on solid silver amalgam electrode is introduced. A well-defined peak for the oxidation of Mn(0) to Mn(II) was observed around À 1.45 V in NH 4 Cl (0.05 M) solution. Concentrations down to 1 mg/L were measured in NH 4 Cl (0.05 M) with 900 s deposition time at À 1.70 V, and good linearity was observed (r 2 avg ¼ 0.993) for standard additions in different concentration ranges (1 -3 mg/L, 10 mg/L -60 mg/L, and 50 mg/L -250 mg/L). For… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
1

Year Published

2009
2009
2017
2017

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 45 publications
0
5
0
1
Order By: Relevance
“…Respective limits of detection of 63 nM and 36 nM for manganese(II) were determined at the drSPE and prSPE. Such low limits of detection offered by the prSPE highlight the excellent electroanalytical applicability of the recessed electrode and improve even over previous reports at an array of recessed electrodes, which boasted a limit of detection of 64 nM, 4 which itself was superior over analytical reports such as spectrophotometric techniques 54 and flow-injection with flame atomic absorption spectrometry, 55 and electroanalytical protocols; [56][57][58][59][60] such a response indicates the greater current density observed at the prSPE due to the greater proportion of edges (point diffusion/mass transport), thus highlighting the beneficial utilisation of the prSPE. We have demonstrated the successful fabrication of highly novel screen printed shallow recessed electrodes.…”
Section: Pentagon-shaped Screen Printed Shallow Recessed Electrodesmentioning
confidence: 66%
“…Respective limits of detection of 63 nM and 36 nM for manganese(II) were determined at the drSPE and prSPE. Such low limits of detection offered by the prSPE highlight the excellent electroanalytical applicability of the recessed electrode and improve even over previous reports at an array of recessed electrodes, which boasted a limit of detection of 64 nM, 4 which itself was superior over analytical reports such as spectrophotometric techniques 54 and flow-injection with flame atomic absorption spectrometry, 55 and electroanalytical protocols; [56][57][58][59][60] such a response indicates the greater current density observed at the prSPE due to the greater proportion of edges (point diffusion/mass transport), thus highlighting the beneficial utilisation of the prSPE. We have demonstrated the successful fabrication of highly novel screen printed shallow recessed electrodes.…”
Section: Pentagon-shaped Screen Printed Shallow Recessed Electrodesmentioning
confidence: 66%
“…ASV of Mn in NH 4 Cl has been done and shown to give repeatable and reliable results on a rotating solid silver amalgam electrode in 0.05 M NH 4 Cl solution [32]. For this reason, aqueous solutions consisting of 0.05 M NH 4 Cl (pH 4.5) with 1.5 mM Mn 2+ were prepared and studied using cyclic voltammetry on MCFCNT electrodes to characterize the redox behavior of Mn.…”
Section: Resultsmentioning
confidence: 99%
“…Tanto o procedimento de amalgamação natural como o de amalgamação mecânica possibilitam que eletrodos de diferentes áreas geométricas e diferentes formas possam ser facilmente construídos, inclusive eletrodos rotatórios. 47 Além disto, SAE com diferentes composições entre metal e mercúrio podem ser facilmente obtidos para aplicações especiais, tais como em processos redox, onde podem ocorrer interações específicas entre o analito e o metal da amálgama, como as reações que ocorrem com os aminoácidos. 10 A formação de complexos entre o analito de interesse e o metal do SAE também pode promover uma considerável melhora na seletividade analítica e pode ser facilmente observada, devido à simplicidade na preparação de SAE.…”
Section: Fácil Construçãounclassified