2022
DOI: 10.20964/2022.12.12
|View full text |Cite
|
Sign up to set email alerts
|

Determination of Metandienone using molecularly Imprinted based Electrochemical Sensor in human urine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 46 publications
0
2
0
Order By: Relevance
“…The sensor was selective to MD, and no interference effects were observed with interferants that tested 10-fold more concentrated (e.g., testosterone, glutamic acid, 19-NT, boldenone, stanozolone, keto-testosterone, methylboldenone, progesterone, methyltestosterone, b-estradiol, a-testosterone, acetaminophen, uric acid, dehydroepiandrosterone, a-nortestosterone, a-boldenone, keto-nortestosterone, and clenbuterol). The sensor was used to detect MD in urine samples, and the results obtained were approximately 5 ng/mL with RSD values between 3.15 and 4.73% [ 134 ]. Finally, Zheng and Lu fabricated an MIP sensor for the detection of stanozolone, which is a synthetic anabolic steroid.…”
Section: Detection Of Skeletal and Cardiac Muscle Analytes With Mipsmentioning
confidence: 99%
“…The sensor was selective to MD, and no interference effects were observed with interferants that tested 10-fold more concentrated (e.g., testosterone, glutamic acid, 19-NT, boldenone, stanozolone, keto-testosterone, methylboldenone, progesterone, methyltestosterone, b-estradiol, a-testosterone, acetaminophen, uric acid, dehydroepiandrosterone, a-nortestosterone, a-boldenone, keto-nortestosterone, and clenbuterol). The sensor was used to detect MD in urine samples, and the results obtained were approximately 5 ng/mL with RSD values between 3.15 and 4.73% [ 134 ]. Finally, Zheng and Lu fabricated an MIP sensor for the detection of stanozolone, which is a synthetic anabolic steroid.…”
Section: Detection Of Skeletal and Cardiac Muscle Analytes With Mipsmentioning
confidence: 99%
“…This modulates the electron concentration in WO 3 , thereby changing its electrical conductivity. For oxidizing gases, electrons are extracted from the conduction band leading to increased resistance [ [15] , [16] , [17] , [18] , [19] ]. Reducing gases inject electrons into the conduction band and cause decreased resistance [ 13 ].…”
Section: Introductionmentioning
confidence: 99%