Abstract: A novel integrated acoustooptic tunable filter (IAOTF) has been developed. This tunable filter is based on the Bragg interactions between waveguide and surface acoustic waves. Compared to (bulk) AOTF, its advantage include all-fiber construction, smaller size, narrower spectral resolution (1.7 nm), higher diffraction efficiency (37%), and lower rf power requirement (150 mW). A relatively narrow spectral tuning range (about 80 nm) is the only drawback for this integrated tunable filter. However, this disadvanta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2000
2000
2005
2005

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…Instrumentation. The NIR spectrophotometer used in this work was the same as that used in our previous studies. The only difference between the spectrometer used in this work and that used previously is that two identical 1-mm core optical fibers were used to direct the light from the sample beam to the sample and from the sample to the InGaAs detector. This modification was made to facilitate measurements of peptides directly in the reaction chamber cell.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Instrumentation. The NIR spectrophotometer used in this work was the same as that used in our previous studies. The only difference between the spectrometer used in this work and that used previously is that two identical 1-mm core optical fibers were used to direct the light from the sample beam to the sample and from the sample to the InGaAs detector. This modification was made to facilitate measurements of peptides directly in the reaction chamber cell.…”
Section: Methodsmentioning
confidence: 99%
“…13.14 As a consequence of this development, a NIR spectrophotometer based on the AOTF should be very sensitive, should have high light throughput, high stability, and no drift. In fact, we recently developed an AOTF-based NIR spectrometer and successfully used it for a variety of spectroscopic and analytical measurements including the determination of trace amounts of monomethylhydrazine and the study of inclusion complex formation between cyclodextrins and aromatic compounds, as well as the detector for flow injection analysis. …”
mentioning
confidence: 99%
“…As a consequence of this development, a NIR spectrophotometer based on the AOTF should be very sensitive, should have high light throughput, high stability, and no drift. In fact, we recently developed an AOTF-based NIR spectrometer and successfully used it for a variety of spectroscopic and analytical measurements, including the determination of trace amounts of monomethylhydrazine and the study of the inclusion complex formation between cyclodextrins and aromatic compounds, as well as the detector for flow injection analysis (5)(6)(7)(8)(9).…”
Section: Fig 2 (A)mentioning
confidence: 99%