2008
DOI: 10.1016/j.talanta.2008.06.015
|View full text |Cite
|
Sign up to set email alerts
|

Determination of pesticides fenoxycarb and permethrin by sequential injection chromatography using miniaturized monolithic column

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
12
0
1

Year Published

2010
2010
2020
2020

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 32 publications
(14 citation statements)
references
References 20 publications
1
12
0
1
Order By: Relevance
“…The peak asymmetry of lignans on a particulate Ascentis Express column 1.00-1.10 was lower than that on a Chromolith column. This fi nding agrees with earlier observation found for phenol, N,N-dimethylaniline and toluene (Wu et al, 2004) and pesticides (Chocholouš et al, 2008). They showed that the tailing on monolithic columns was higher than packed columns for acidic, basic, and even neutral compounds.…”
Section: Hplcsupporting
confidence: 93%
“…The peak asymmetry of lignans on a particulate Ascentis Express column 1.00-1.10 was lower than that on a Chromolith column. This fi nding agrees with earlier observation found for phenol, N,N-dimethylaniline and toluene (Wu et al, 2004) and pesticides (Chocholouš et al, 2008). They showed that the tailing on monolithic columns was higher than packed columns for acidic, basic, and even neutral compounds.…”
Section: Hplcsupporting
confidence: 93%
“…A Cheminert® Valco10-port multi-position valve (SV) model C25 stream selector C25-3180 EMH (Valco Instruments, Houston, TX, USA) was used to select and drive sample and mobile phase solutions though the system. Port 2 of SV is connected to a 5 mm long guard column coupled to a 25 mm reverse phase C 18 Chromolith Flash monolithic column, both from Merck KGaA (Darmstadt, Germany). Detection was made by molecular absorbance spectrophotometry using an USB 4000 spectrometer (Ocean Optics, Dunedin, An LC 9A Shimadzu high performance liquid chromatograph (HPLC), equipped with a SPD 6 AV UV detector and the LC Workstation Class-LC 10 software was used in comparison studies.…”
Section: A Sichrommentioning
confidence: 99%
“…Electroanalytical methods are known to attend the demand for minimal sample treatment and low consumption of organic solvents, 12,13 but these techniques are liable to matrix effects such as passivation 15 and the low backpressures provided by C 18 monolithic stationary phases. This technique uses low cost instrumentation and has been applied especially in the determination of components of pharmaceutical products, 16 although determinations of herbicides and pesticides 17,18 and amino acids 19 have been described. The present paper shows that the SIC capabilities for separation of simple mixtures can be explored for monitoring the maximum concentration levels of picloram in natural waters.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A zona de amostra transportada através da coluna monolítica pela fase móvel, sendo a detecção espectrofotométrica realizada em 210 nm. As medidas foram baseadas na altura dos picos como em procedimentos desenvolvidos anteriormente em SIC [35,50]. Todos os experimentos foram realizados em triplicata em temperatura ambiente (25ºC).…”
Section: Procedimentounclassified