2017
DOI: 10.1088/1681-7575/aa77d1
|View full text |Cite
|
Sign up to set email alerts
|

Determination of the Avogadro constant by the XRCD method using a28Si-enriched sphere

Abstract: The revision of the SI-the result of three decades of progress in metrology Michael Stock et al

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
51
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 46 publications
(51 citation statements)
references
References 41 publications
0
51
0
Order By: Relevance
“…Also notable was the use of the high axial frequency of 3.5 MHz, which reduces some anharmonic shifts and leads to a lower cyclotron temperature after cyclotron-to-axial coupling. The third is a measurement by the SMILETRAP group [75] using their time-of-flight detection technique to measure the CFRs of H 2 + relative to several charge states of 12 C, but also of 28 Si, 14 N, 20 Ne, and 40 Ar, making use of measurements of these atoms at the 10 −10 level by MIT [41]. The fourth is another measurement by the SMILETRAP group [38], but making use of the Ramsey variant of their TOF method, and measuring H 2 + against D + as a reference.…”
Section: Protonmentioning
confidence: 99%
“…Also notable was the use of the high axial frequency of 3.5 MHz, which reduces some anharmonic shifts and leads to a lower cyclotron temperature after cyclotron-to-axial coupling. The third is a measurement by the SMILETRAP group [75] using their time-of-flight detection technique to measure the CFRs of H 2 + relative to several charge states of 12 C, but also of 28 Si, 14 N, 20 Ne, and 40 Ar, making use of measurements of these atoms at the 10 −10 level by MIT [41]. The fourth is another measurement by the SMILETRAP group [38], but making use of the Ramsey variant of their TOF method, and measuring H 2 + against D + as a reference.…”
Section: Protonmentioning
confidence: 99%
“…[] and references herein) and silicon‐sphere (aka XRCD or Avogadro; see refs. [] and references herein) experiments, which helped to remove inconsistencies that had been revealed in the intermediate CODATA adjustments from 2010 . With respect to future QMT experiments, the new benchmark figures from the latest CODATA adjustment need to be discussed: these impose that significant impact on the Josephson and quantum Hall relations (in the sense of an increase of confidence) now requires closing the QMT with an uncertainty of one part in 10 8 or better.…”
Section: Applications Of Single‐electron Pumps As Quantum Current Stamentioning
confidence: 99%
“…The noted scientific articles belong to CoP SI ≡ LMТF [32][33][34][35][36][37][38]. The values of absolute and relative uncertainties differ by more than a factor of three.…”
Section: Xrcdmentioning
confidence: 99%