1971
DOI: 10.1016/0029-554x(71)90687-2
|View full text |Cite
|
Sign up to set email alerts
|

Determination of the neutrino spectrum in the CERN 1967 neutrino experiment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0

Year Published

1975
1975
2010
2010

Publication Types

Select...
4
2
2

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(20 citation statements)
references
References 2 publications
0
20
0
Order By: Relevance
“…Thus, the muon flux may be used to both monitor and measure the neutrino flux. Numerous past experiments, going nearly as far back as the first accelerator neutrino beam experiment in the early 1960's, have used muon monitoring systems to monitor their tertiary beams and to infer or constrain the fluxes to the experiment [12,13,14,15,16,17].…”
Section: Past Cross Section Experimentsmentioning
confidence: 99%
See 2 more Smart Citations
“…Thus, the muon flux may be used to both monitor and measure the neutrino flux. Numerous past experiments, going nearly as far back as the first accelerator neutrino beam experiment in the early 1960's, have used muon monitoring systems to monitor their tertiary beams and to infer or constrain the fluxes to the experiment [12,13,14,15,16,17].…”
Section: Past Cross Section Experimentsmentioning
confidence: 99%
“…One such beam that used muon monitors is the 1967 CERN PS neutrino beam [13], shown in Figure 1.10. Muons from π/K → µν were ranged out by ∼20 m of shielding upstream of the neutrino detector.…”
Section: Past Cross Section Experimentsmentioning
confidence: 99%
See 1 more Smart Citation
“…To cut off the largest range of neutrino energies, it is desirable to eliminate those particles which travel through the field-free "necks" of the horns. Such was attempted at CERN [177,58] by placing a Tungsten block (beam "plug") at the end of the usual target to help attenuate those high energy pions which tend to leave the target at small angles (θ π ≈ 2/γ π ).…”
Section: Horn Beam With Plugmentioning
confidence: 99%
“…Following experience at BNL [12], the CERN PS [13], and IHEP [14], we propose to use the three NuMI muon alcoves to measure the differential energy distribution of the neutrino flux. Unlike these previous beam lines, however, NuMI has only 3 muon alcoves (See Figure 1), so cannot perform a differential measurement by measuring the flux of muons above each of the 4, 8, and 18 GeV/c momentum thresholds of the alcoves (to be contrasted with the 7-12 muon stations in previous beam lines).…”
Section: Measuring the Neutrino Fluxmentioning
confidence: 99%