Determination of the ubiquinol-10 and ubiquinone-10 (coenzyme Q10) in human serum by liquid chromatography tandem mass spectrometry to evaluate the oxidative stress

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
43
0
1

Year Published

2008
2008
2017
2017

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 67 publications
(46 citation statements)
references
References 33 publications
2
43
0
1
Order By: Relevance
“…In previously reported LC-MS-based assays for CoQ10 in biological samples, either CoQ11 (14 ), CoQ9 (15)(16)(17)19 ), or dipropoxy-CoQ10 (18 ) has been used as the IS. A potential source of error for MS assays is ionization suppression that varies during a chromatographic run and between the samples.…”
Section: Discussionmentioning
confidence: 99%
“…In previously reported LC-MS-based assays for CoQ10 in biological samples, either CoQ11 (14 ), CoQ9 (15)(16)(17)19 ), or dipropoxy-CoQ10 (18 ) has been used as the IS. A potential source of error for MS assays is ionization suppression that varies during a chromatographic run and between the samples.…”
Section: Discussionmentioning
confidence: 99%
“…Eluates were monitored by photodiode-array detector at three wavelengths, as we have previously described (Quesada et al, 2004). Coenzyme Q10 (CoQ10A or Q10, also known as ubiquinone-10) was determined by liquid chromatography coupled with tandem mass-spectrometry (LC-MS/MS), with electrospray ionization, as we have reported (Ruiz-Jiménez et al, 2007).…”
Section: Postmenopausal-women Treatment and Serum Analysesmentioning
confidence: 99%
“…The sensitivity of the proposed HPLC-CL method was approximately 60 times and 10 times higher than those of HPLC-UV [8] and HPLC with post-column colorimetric reaction method [9], respectively. Additionally, the sensitivity was almost comparable to those of HPLC-ECD with catalytic reduction [10], HPLC-ECD with electroreduction [11], HPLC-MS/MS [12] and ultra-performance liquid chromatography with mass spectrometry (UPLC-MS) [17] in spite of the complexity of the proposed detection system was lower compared to those of these methods.…”
Section: Calibration Curve and Detection Limitmentioning
confidence: 99%
“…Several analytical methods have been developed for the determination of ubiquinone in blood samples using high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection [8,9], electrochemical detection (ECD) [10,11] and tandem mass spectrometry (MS/MS) [12]. However, HPLC-UV methods lack sensitivity and suffer from interferences due to co-existing substances.…”
Section: Introductionmentioning
confidence: 99%