2010
DOI: 10.1016/j.fct.2010.03.023
|View full text |Cite
|
Sign up to set email alerts
|

Determination of total mercury in chicken feed, its translocation to different tissues of chicken and their manure using cold vapour atomic absorption spectrometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
1
1

Year Published

2011
2011
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 46 publications
(19 citation statements)
references
References 22 publications
0
17
1
1
Order By: Relevance
“…Généralement, une faible proportion des ETM présents dans la lumière intestinale est absorbée. Les ETM sont dans l'ensemble rapidement excrétés (Dozier et al 2003, Bolan et al 2004, Zhuang et al 2009, Shah et al 2010. Ainsi, Sell (1975) a montré qu'environ 80% de la dose administrée en Cd pouvait être excrétée via les fèces, en 24 heures chez des volailles.…”
Section: / Mécanismes De Transfert Des Polluants Inorganiquesunclassified
“…Généralement, une faible proportion des ETM présents dans la lumière intestinale est absorbée. Les ETM sont dans l'ensemble rapidement excrétés (Dozier et al 2003, Bolan et al 2004, Zhuang et al 2009, Shah et al 2010. Ainsi, Sell (1975) a montré qu'environ 80% de la dose administrée en Cd pouvait être excrétée via les fèces, en 24 heures chez des volailles.…”
Section: / Mécanismes De Transfert Des Polluants Inorganiquesunclassified
“…Homogenized studied samples were stored in polyethylene bottles in desiccators. The ash yield was also determined by standard test method [33], to weighed 5.0 g, of each solid sample in separate crucibles, then placed in a muffle furnace and heated up with stepwise temperature increase up to 6008C for 6 h. The solid matrices and water 1:10 suspensions were prepared and kept overnight at room temperature for physicochemical parameter measurement [31].…”
Section: Physicochemical Parametersmentioning
confidence: 99%
“…Moisture was determined by an electric oven at 100 6 58C till constant weight [32]. The ash yield was also determined by standard test method [33], to weighed 5.0 g, of each solid sample in separate crucibles, then placed in a muffle furnace and heated up with stepwise temperature increase up to 6008C for 6 h.…”
Section: Physicochemical Parametersmentioning
confidence: 99%
“…They include: cold vapor atomic absorption spectrometry [2], complexation and spectrophotometric determination [3], coated magnetic nanoparticle adsorbents [4], inorganic sorbents and adsorbents [5,6], interaction with resins [7,8], solvent extraction [9], flame and graphite atomic absorption spectrometry [10], HPLC [11], high-performance thin layer chromatography (HP-TLC) [12], ion imprinted copolymers [13], and functionalized activated carbon [14].…”
Section: Introductionmentioning
confidence: 99%