2008
DOI: 10.1016/j.nimb.2008.04.011
|View full text |Cite
|
Sign up to set email alerts
|

Determination of uranium content in Th, U mixed oxides using EDXRF

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2009
2009
2015
2015

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(11 citation statements)
references
References 9 publications
0
11
0
Order By: Relevance
“…Various approaches like internal standard, matrix dilution, thin‐film, mathematical correction, etc.,5 are used for taking care of the matrix effects. Calibration plots in the form of polynomial equations for uranium and thorium determinations in their mixed oxides are reported in literature 9. However, such methods can be used for the analysis of samples having their matrix similar to that of the calibration standards.…”
Section: Introductionmentioning
confidence: 99%
“…Various approaches like internal standard, matrix dilution, thin‐film, mathematical correction, etc.,5 are used for taking care of the matrix effects. Calibration plots in the form of polynomial equations for uranium and thorium determinations in their mixed oxides are reported in literature 9. However, such methods can be used for the analysis of samples having their matrix similar to that of the calibration standards.…”
Section: Introductionmentioning
confidence: 99%
“…There are a number of advantages for choice of Cu as internal standard such as (i) closeness of its fluorescence line with Fe, (ii) their fluorescence lines are well resolved and (ii) both the elements are excited by fluorescence energy of Ge simultaneously. A lot of literatures are available on use of internal standard for element determination using EDXRF and Total X-ray fluorescence (TXRF) techniques in solid as well as in liquid samples [22][23][24]. The concentration of internal standard (Cu) was decided on the basis of literature data used for determination of uranium in 0.5 M D2EHPA ?…”
Section: Resultsmentioning
confidence: 99%
“…Duplicate samples were prepared and measured by using Rh target Minipal4 PANalytical bench-top EDXRF and the tube ratings were set to 300 mV, 150 µA and using Mo filter with 100 second measurement. Calibration was carried out by measuring Lα line for U, Th and Pb (Natarajan et al, 2008;Yu et al, 2002). Standard Reference Material IAEA 312, IAEA 313, IAEA SL-1, IAEA Soil 7 and IAEA SL-1 for U and Pb, while for Th Standard IAEA RG-Th-1 was used for calibration.…”
Section: Alpha Spectrometry Measurementmentioning
confidence: 99%