1998
DOI: 10.1039/a708836a
|View full text |Cite
|
Sign up to set email alerts
|

Determination of zirconium with Xylenol Orange by flow injection spectrophotometry: application to eluates from technetium-99m generators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2003
2003
2016
2016

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 29 publications
0
5
0
Order By: Relevance
“…UV-Vis spectrophotometric methods have been widely used due to simplicity, rapidity, low costs and wide applications [23][24][25][26]. For this purpose, widely-used chromogenic reagents are pyrocatechol violet [27], alizarin red S [28][29][30], arsenazo I and III [27][28][29][30][31], xylenol orange [21,[34][35][36][37], Janus Green dye [38], 2,4-dinitrophenol-(6-azo-2)-1-napthol-3,8-disulphonic acid (picramine <epsilon>) [39], 2-(6-bromo-2-benothiaoylazo) 5-diethylaminophenol and sodium lauryl sulphate [40], 4-(2-pyridiylazo) resorcinol (PAR) [41,42], 2-(5-bromo-2-pyridylazo)-5-(diethylamino)phenol [43], 5,7-dibromo-8-hydroxylquinoline [44], chorme azurol S [45], for determination of Zr(IV) by spectrophotometry was reported. Some methods have low sensitivity and selectivity and others have high sensitivity but low selectivity.…”
Section: Page 3 Of 30mentioning
confidence: 99%
See 1 more Smart Citation
“…UV-Vis spectrophotometric methods have been widely used due to simplicity, rapidity, low costs and wide applications [23][24][25][26]. For this purpose, widely-used chromogenic reagents are pyrocatechol violet [27], alizarin red S [28][29][30], arsenazo I and III [27][28][29][30][31], xylenol orange [21,[34][35][36][37], Janus Green dye [38], 2,4-dinitrophenol-(6-azo-2)-1-napthol-3,8-disulphonic acid (picramine <epsilon>) [39], 2-(6-bromo-2-benothiaoylazo) 5-diethylaminophenol and sodium lauryl sulphate [40], 4-(2-pyridiylazo) resorcinol (PAR) [41,42], 2-(5-bromo-2-pyridylazo)-5-(diethylamino)phenol [43], 5,7-dibromo-8-hydroxylquinoline [44], chorme azurol S [45], for determination of Zr(IV) by spectrophotometry was reported. Some methods have low sensitivity and selectivity and others have high sensitivity but low selectivity.…”
Section: Page 3 Of 30mentioning
confidence: 99%
“…Different spectroanalytical techniques such as molecular fluorescence spectrophotometry [3], atomic absorption spectroscopy (AAS) [4], inductively coupled plasma-optical emission spectrometry (ICP-OES) [5,6], laser ablation inductively coupled plasma optical emission spectrometry (LAICP-OES) [7], Xray fluorescence spectroscopy (XRF) [8,9], induced plasma atomic emission spectrometry (ICP-AES) [10][11][12][13], and UV-Vis spectrophotometry [18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35][36][37]. Other…”
Section: Introductionmentioning
confidence: 99%
“…Abdul Majeed and Khan M, 1987; Grudpan et al, 1998, they have used XO for selective agent for determination of zirconium by spectrophotometer. Their method has been successful in determination zirconium in NBS steel and eluate from technetium-99m generator samples [11][12].…”
Section: Introductionmentioning
confidence: 99%
“…Spectrophotometric methods occupy special position due to their simplicity, less expensive instrumentation and high sensitivity. Many methods of zirconium determination have been published [1,[3][4][5][6][14][15][16][17]. However, some of these methods have both low sensitivity and low selectivity while others have high sensitivity but low selectivity in presence of some ions or molecules.…”
Section: Introductionmentioning
confidence: 99%
“…There are numerous methods outlined for determination of Zr (IV) in literature [3][4][5][6][7][8][9]. Trace amounts of zirconium have been determined by X-ray fluorescence, neutron activation, atomic emission and spectrophotometry (10)(11)(12)(13)(14)(15) . Spectrophotometric methods occupy special position due to their simplicity, less expensive instrumentation and high sensitivity.…”
Section: Introductionmentioning
confidence: 99%