2019
DOI: 10.15587/1729-4061.2019.155672
|View full text |Cite
|
Sign up to set email alerts
|

Determining additional power losses in the electricity supply systems due to current's higher harmonics

Abstract: current higher harmonics to the loss of power, to the magnitude of total losses. This is important because the past decades have seen an increase in the number of electric energy pulse consumers, which relates both to household appliances and industrial equipment. That leads to an increase in the content of currents higher harmonics in the electricity supply systems and, consequently, to the increased power losses associated with higher harmonics, which necessitate the use 6

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
5

Relationship

5
5

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 13 publications
0
6
0
Order By: Relevance
“…Postgraduate Student** Е-mail: D.Hordiienko@i.ua The THD parameter reflects the percentage of the higher harmonics relative to the first harmonic's voltage signal. In turn, the higher harmonics cause a series of negative effects in the power supply systems and various loads, which include the faster aging of insulation, electromagnetic interference with communication systems, as well as additional power losses in the active resistance of power supply systems and windings of induction motors [13].…”
Section: H O R D I I E N K Omentioning
confidence: 99%
“…Postgraduate Student** Е-mail: D.Hordiienko@i.ua The THD parameter reflects the percentage of the higher harmonics relative to the first harmonic's voltage signal. In turn, the higher harmonics cause a series of negative effects in the power supply systems and various loads, which include the faster aging of insulation, electromagnetic interference with communication systems, as well as additional power losses in the active resistance of power supply systems and windings of induction motors [13].…”
Section: H O R D I I E N K Omentioning
confidence: 99%
“…The differential equations ( 7), ( 8) were solved by the Runge-Kutta method in the Mathcad programming suite [17][18][19][20].…”
Section: Modeling the Longitudinal Loading On A Train Equipped With Nmentioning
confidence: 99%
“…To determine the energy-saving effect from implementing the improved hysteresis algorithm of hysteresis modulation, we calculated power losses in the active four-quadrant converter at its output voltage of 3,000 V [24].…”
Section: Determining Power Losses In Power Keysmentioning