2020
DOI: 10.1021/acs.analchem.0c01399
|View full text |Cite
|
Sign up to set email alerts
|

Determining the Regiochemistry and Relative Stereochemistry of Small and Druglike Molecules Using an Alignment Algorithm for Infrared Spectra

Abstract: The relative stereochemistry and isomeric substitution pattern of organic molecules is typically determined using nuclear magnetic resonance spectroscopy (NMR). However, NMR spectra are sometimes nonconclusive, e.g., if spectra are extremely crowded, coupling patterns are not resolved, or if symmetry reasons preclude interpretation. Infrared spectroscopy (IR) can provide additional information in such cases, because IR represents a molecule comprehensively by depiction of the complete set of its normal vibrati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
27
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 14 publications
(27 citation statements)
references
References 17 publications
0
27
0
Order By: Relevance
“…Vibrational circular dichroism (VCD) spectroscopy is chiroptical spectroscopy that extends circular dichroism into the infrared region. Even a molecule with no electronic absorption in the ultraviolet–visible (UV–vis) region can be a target. VCD spectra are typically measured 10 4 –10 5 times for several hours on repeated scans to obtain reliable results.…”
mentioning
confidence: 99%
“…Vibrational circular dichroism (VCD) spectroscopy is chiroptical spectroscopy that extends circular dichroism into the infrared region. Even a molecule with no electronic absorption in the ultraviolet–visible (UV–vis) region can be a target. VCD spectra are typically measured 10 4 –10 5 times for several hours on repeated scans to obtain reliable results.…”
mentioning
confidence: 99%
“…Peak alignment was done based on the IRSA algorithm originally developed by Riniker and co-workers. 71 Figure 3 shows the computational and experimental results, for which we adapted the recently presented IRSA algorithm by Riniker and co-workers to continuous spectral densities. 71 Hence, the computational peaks are aligned to their experimental pendants, using a scoring function for peak position and intensity, in order to facilitate the comparison between simulated and experimental spectra (see the SI for details).…”
Section: ∆ Pbcmentioning
confidence: 99%
“…71 Figure 3 shows the computational and experimental results, for which we adapted the recently presented IRSA algorithm by Riniker and co-workers to continuous spectral densities. 71 Hence, the computational peaks are aligned to their experimental pendants, using a scoring function for peak position and intensity, in order to facilitate the comparison between simulated and experimental spectra (see the SI for details). It is important to note that we choose to align the IR spectra, which is more reliable than seeking for an alignment of the congested VCD spectra, but nevertheless improves the significance of predicted VCD peaks.…”
Section: ∆ Pbcmentioning
confidence: 99%
“…The above mentioned workflows have been applied multiple times to elucidate the structure of NPS. While chromatography and mass spectrometry are most often used in complementarity with NMR, IR and Raman spectroscopies are rather used as optional tools, and little details are given in the literature [14][15][16].…”
Section: Introductionmentioning
confidence: 99%