Determining the relative effectiveness of islanding detection methods using phase criteria and nondetection zones

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
122
0
9

Year Published

2002
2002
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 278 publications
(131 citation statements)
references
References 5 publications
0
122
0
9
Order By: Relevance
“…To avoid lengthening this report excessively, all of those mappings are not repeated here, but the reader is encouraged to review references [1,2,3]. All grid-connected PV inverters are required to have over/under frequency protection methods (OFP/UFP) and over/under voltage protection methods (OVP/UVP) that cause the PV inverter to stop supplying power to the utility grid if the frequency or amplitude of the voltage at the point of common coupling (PCC) between the customer and the utility strays outside of prescribed limits.…”
Section: Methods For Detection Of Islandingmentioning
confidence: 99%
See 1 more Smart Citation
“…To avoid lengthening this report excessively, all of those mappings are not repeated here, but the reader is encouraged to review references [1,2,3]. All grid-connected PV inverters are required to have over/under frequency protection methods (OFP/UFP) and over/under voltage protection methods (OVP/UVP) that cause the PV inverter to stop supplying power to the utility grid if the frequency or amplitude of the voltage at the point of common coupling (PCC) between the customer and the utility strays outside of prescribed limits.…”
Section: Methods For Detection Of Islandingmentioning
confidence: 99%
“…Because of this concern, the standard over/under voltage and frequency protective devices alone are generally considered to be insufficient anti-islanding protection. A mapping of the NDZ of the four standard over/under voltage and frequency protection methods in the RLC load space and the DP-DQ space can be found in the literature [1,3]. As an example, the NDZ of the over/under frequency protective devices in the RLC load space is plotted in Figure 2a.…”
Section: Ndzmentioning
confidence: 99%
“…The passive techniques look for some parameter deviations like voltage magnitude [7], rate of change of frequency [8], harmonics [9], or Phase angle displacement [10]. In the islanding mode, these parameters vary largely at the PCC.…”
Section: Passive Islanding Methodsmentioning
confidence: 99%
“…Na Tabela 2.2 podem ser vistas as expressões do critério de fase para os métodos anti-ilhamento mais comuns, de acordo com (ROPP et al, 2000).…”
Section: Região De Não Detecção (Ndz)unclassified
“…Contudo, para cada valor de é necessário plotar curvas diferentes. A expressão de é dada por (ROPP et al, 2000):…”
Section: Tabela 22 Critérios De Fase Dos Principais Métodos Ativosunclassified