Determining Urea Levels in Exhaled Breath Condensate with Minimal Preparation Steps and Classic LC-MS

Abstract: Exhaled breath condensate (EBC) provides a relatively easy, noninvasive method for measuring biomarkers of inflammation and oxidative stress in the airways. However, the levels of these biomarkers in EBC are influenced, not only by their levels in lung lining fluid but also by the volume of water vapor that also condenses during EBC collection. For this reason, the use of a biomarker of dilution has been recommended. Urea has been proposed and utilized as a promising dilution biomarker due to its even distribu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(10 citation statements)
references
References 32 publications
0
10
0
Order By: Relevance
“…We examined the correlation between paired blow samples as absolute cortisol concentrations (i.e., pg/ml) or urea‐normalized cortisol concentrations (ng/mg urea). Since urea is thought to remain relatively stable and constant in an individual (Dwyer, 2004; Esther et al, 2009; Pitiranggon et al, 2014) and should be negligible in the surrounding environment, we expected to see a correlation between paired urea‐normalized cortisol concentrations, as urea should account for any seawater dilution.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…We examined the correlation between paired blow samples as absolute cortisol concentrations (i.e., pg/ml) or urea‐normalized cortisol concentrations (ng/mg urea). Since urea is thought to remain relatively stable and constant in an individual (Dwyer, 2004; Esther et al, 2009; Pitiranggon et al, 2014) and should be negligible in the surrounding environment, we expected to see a correlation between paired urea‐normalized cortisol concentrations, as urea should account for any seawater dilution.…”
Section: Methodsmentioning
confidence: 99%
“…Since urea is thought to remain relatively stable and constant in an individual (Dwyer, 2004;Esther et al, 2009;Pitiranggon et al, 2014) and should be negligible in the surrounding environment, we expected to see a correlation between paired urea-normalized cortisol concentrations, as urea should account for any seawater dilution.…”
Section: Sample Normalizationmentioning
confidence: 99%
See 1 more Smart Citation
“…A standard procedures with UV-Vis spectrophotometry is still been applied for urea where this analytical protocol is subject to interference from interfering species (Situmorang, et al, 2010). Another methods for urea determination have been introduces such as reflectometry (Ulianas, et al, 2011;Alqasaimeh, et al, 2007), colorimetry (Gaddes, et al, 2015;Zawada, et al, 2009;Sharma, et al, 2009), nuclear magnetic resonance (Liu, et al, 2012), LC-MS (Pitiranggon, et al, 2014), field effect transistor (Chang, et al, 2010;Lue, et al, 2011), acoustic wave (Tan, et al, 1998), and electrochemical methods (Ma, et al, 2016;Manea, et al, 2008;Ho, et al, 1999; Hilding-Ohlsson, et al, 2012; Das and Yoon, 2015). Most of the previous methods are operated with relatively expensive instrumentation.…”
Section: Introductionmentioning
confidence: 99%
“…EBC is suitable for metabolomics analysis and may be a good approach to studying lung reactions during shock or lung diseases, based on standardized EBC sample collection [ 18 , 19 ]. Although some metabolomics works have been published on this fluid, based on LC-MS, GC-MS [ 20 , 21 , 22 , 23 , 24 , 25 ] or NMR [ 26 , 27 ], such an approach has never been applied to explore shock pathophysiology.…”
Section: Introductionmentioning
confidence: 99%