2017
DOI: 10.1177/1934578x1701201105
|View full text |Cite
|
Sign up to set email alerts
|

Developing a Validated HPLC Method for the Phytochemical Analysis of Antihyperuricemic Phenylethanoid Glycosides and Flavonoids in Lippia nodiflora

Abstract: The phenylethanoid glycosides and flavonoids of Lippia nodiflora were reported as xanthine oxidase inhibitors that possessed antihyperuricemic effects in chemically-induced hyperuricemic rats. The present study developed a validated high performance liquid chromatography method for the simultaneous phytochemical analysis of five isolated antihyperuricemic constituents in L. nodiflora, comprising two phenylethanoid glycosides, arenarioside (1) and verbascoside (2), and three flavonoids, 6-hydroxyluteolin (3), 6… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(7 citation statements)
references
References 15 publications
0
7
0
Order By: Relevance
“…The method was validated through intraday and inter-day analysis of precision and accuracy according to the International Conference on Harmonisation guidelines [33]. The intraday accuracy and precision were determined for each compound by evaluating six replicate measurements of each concentration on a single day, while the inter-day accuracy and precision were determined by assessing measurements of each concentration over 6 consecutive days [24]. The recovery of the direct extraction method using methanol was calculated by comparing the peak area of the compounds after extraction with those of the compounds dissolved in the methanol at a similar concentration [24].…”
Section: Methods Validationmentioning
confidence: 99%
See 4 more Smart Citations
“…The method was validated through intraday and inter-day analysis of precision and accuracy according to the International Conference on Harmonisation guidelines [33]. The intraday accuracy and precision were determined for each compound by evaluating six replicate measurements of each concentration on a single day, while the inter-day accuracy and precision were determined by assessing measurements of each concentration over 6 consecutive days [24]. The recovery of the direct extraction method using methanol was calculated by comparing the peak area of the compounds after extraction with those of the compounds dissolved in the methanol at a similar concentration [24].…”
Section: Methods Validationmentioning
confidence: 99%
“…4), were isolated from the bioactive fraction of L. nodiflora following the protocol described previously [19] and were used as marker compounds for the method validation and quantification of rat plasma samples. The purity of the compounds was determined using an Agilent 1120 Compact LC system equipped with a variable wavelength photometric detector and Agilent EZ-Chrom Elite Compact Software (Agilent Technologies) [24]. The purities were found to be 97.71, 98.19, 96.25, 97.30, and 97.36 % for 1, 2, 3, 4, and 5, respectively.…”
Section: Chemicals and Reagentsmentioning
confidence: 99%
See 3 more Smart Citations