2015 IEEE Advanced Information Technology, Electronic and Automation Control Conference (IAEAC) 2015
DOI: 10.1109/iaeac.2015.7428588
|View full text |Cite
|
Sign up to set email alerts
|

Developing the intelligent predetermined control method for a new temperature and humidity chamber: A Case study for rising temperature under constant relative humidity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 10 publications
0
5
0
Order By: Relevance
“…PID is also known as proportional integral (PI), proportional derivative (PD), proportional (P), or integral (I) controller. PID controller Mv(t) is based on the combination of three variables as follows: Locally, update the pheromone trails using the local updating rule as in equation 9Globally, update the pheromone trails using the global updating rule in equation (8) Journal of Control Science and Engineering…”
Section: Pid Controller Pid Controller Is a Feedback Control System mentioning
confidence: 99%
See 1 more Smart Citation
“…PID is also known as proportional integral (PI), proportional derivative (PD), proportional (P), or integral (I) controller. PID controller Mv(t) is based on the combination of three variables as follows: Locally, update the pheromone trails using the local updating rule as in equation 9Globally, update the pheromone trails using the global updating rule in equation (8) Journal of Control Science and Engineering…”
Section: Pid Controller Pid Controller Is a Feedback Control System mentioning
confidence: 99%
“…In general, the capacity of ventilation control system based on sprinkle process decreases the energy usage and improves environmental condition. Hung et al [8] studied an interesting controlling method by advance setting of the intelligent predetermined control method (IPCM) in order to improve the use of energy and water. An increase in temperature with a stable RH under the condition of no load is considered to test the possibility of IPMC.…”
Section: Introductionmentioning
confidence: 99%
“…The airflow from the axial fan can move along the chamber walls, significantly reducing instances of dead corners, producing unobstructed circulation, and improving the uniformity of the temperature and relative humidity. Furthermore, to simultaneously solve the problem of interference from the actuators in the same airflow loop, the concept of the independent flow loops is used from the previous study (Hung et al, 2015). In addition, to prevent affecting the airflow from the actuator into the test chamber, the inlet and outlet pipes must be tailored as tangential to the airflow shown in Fig.…”
Section: Design a Cylindrical Chamber With Independent Flow Loopsmentioning
confidence: 99%
“…To refer the former designed precise heating system (Hung et al, 2015), a new-designed precise heating system with a hot wire heater is shown in Fig. 11.…”
Section: Precise Heating Systemmentioning
confidence: 99%
“…In addition, with miniaturized heating and humidifying elements, it is not easy to realize heating and humidifying functions with reasonable range and speed, compared to their macroscopic counterparts. Although control algorithms can be utilized to optimize the heating and humidifying process, most of the reported algorithms are developed for standard "big" environmental chambers [12][13][14]. Their applicability on miniaturized systems still need to be investigated.…”
Section: Introductionmentioning
confidence: 99%