1990
DOI: 10.1080/00986449008940577
|View full text |Cite
|
Sign up to set email alerts
|

Development and Evaluation of a Planar Heat Pipe for Cooling Electronic Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

1998
1998
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 5 publications
0
5
0
Order By: Relevance
“…In 1990, Adami and Yimer [10] constructed a 15.24 cm × 30.48 cm × 1.905 cm FHP with water as the working fluid and three layers of #100 copper mesh as the wicking material. They found that gravitational orientation did not have a significant effect on the performance, and the axial temperature gradient increased nearly linearly with input power.…”
Section: The Development Of Polymer-based Flat Heat Pipes I Introducmentioning
confidence: 99%
“…In 1990, Adami and Yimer [10] constructed a 15.24 cm × 30.48 cm × 1.905 cm FHP with water as the working fluid and three layers of #100 copper mesh as the wicking material. They found that gravitational orientation did not have a significant effect on the performance, and the axial temperature gradient increased nearly linearly with input power.…”
Section: The Development Of Polymer-based Flat Heat Pipes I Introducmentioning
confidence: 99%
“…Test device mainly comprises: (1) vacuum phase change heat transfer working fluid filling system; (2) wind tunnel testing system [1,2]; (3) the electric heating simulation system; (4) measurement system (see Fig. 244.2).…”
Section: Test System Of New Radiatormentioning
confidence: 99%
“…A new radiator heat transfer and flow performance test system based on central processing unit (CPU) chip radiating is established in this paper [1][2][3][4]. The system can be a steady and transient heat transfer test.…”
Section: Introductionmentioning
confidence: 99%
“…They found out the boiling process time of glycerin oil preheated by CLOHP/CV heat exchanger was less than liquefied petroleum gas boiling process (Donmuang et al 2008). This feature makes the use of heat pipes desirable by many researchers: (Zhao et al 2016, Tiari et al 2015, Tiari et al 2016, Mahdavi et al 2018 and electronic cooling by many researchers: (Hassan and Harmand 2013, Adami and Yimer 1990, Peterson 1988, Mozumder et al 2011. Heat pipes which use nanofluids as working fluid are one of the most preferred heat transfer ways because of their rapid effectiveness (Aydin et al 2020: Hoseinzadeh et al 2017.…”
Section: Introductionmentioning
confidence: 99%