Development and evaluation of transfer functions for a variable speed compressor

Abstract: In this study, transfer functions of electronic expansion valve and variable speed scroll compressor in a chiller system are developed based on an experimental analysis. Dynamic behaviours of water temperature at chiller output and refrigerant superheat at evaporator outlet have either the first-or the second-order linear models, respectively. Different from the existing modelling studies in literature novel models are presented for variable speed refrigeration system with scroll compressor and liquid type eva… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
24
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
1
1
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(24 citation statements)
references
References 15 publications
0
24
0
Order By: Relevance
“…In [6], it is assumed that 1 ( ) w A z  and 1 ( ) w B z  are constant, even with different cooling loads. However, since the cooling load may vary by a large amount when the environment of the conditioned space changes, they are considered to be functions of w m  in this work.…”
Section: Problem Formulationmentioning
confidence: 99%
See 2 more Smart Citations
“…In [6], it is assumed that 1 ( ) w A z  and 1 ( ) w B z  are constant, even with different cooling loads. However, since the cooling load may vary by a large amount when the environment of the conditioned space changes, they are considered to be functions of w m  in this work.…”
Section: Problem Formulationmentioning
confidence: 99%
“…Dynamic characteristics of heat transfer in evaporator can be determined by cooling load on the water side and working condition on the refrigerant side. For control purpose, denote wo T y  as system output and compressor speed cp F as input signal u , the following linear model can be built from [6]:…”
Section: Problem Formulationmentioning
confidence: 99%
See 1 more Smart Citation
“…EEV is the first controllable equipment in VSRS (Aprea et al, 2006a,b;Lazzarin and Noro, 2008, 2011. For this controller, two inputs and one output variable were defined in Fig.…”
Section: Fuzzy Logic Controlmentioning
confidence: 99%
“…Therefore, it has been widely used in Heating Ventilation Air Conditioning and Refrigeration (HVAC&R) systems (Jiangjiang et al, 2006). Recently, energy consuming is a strict issue in designing new refrigeration system Ekren et al, , 2011Nasutin andHassan, 2006, Sahin et al, 2010). EEV and VSC have important effect on efficiency of system energy consumption.…”
Section: Introductionmentioning
confidence: 99%