2014
DOI: 10.1016/j.jpba.2014.06.004
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of a novel cell-based assay for potency determination of human parathyroid hormone (PTH)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0
1

Year Published

2015
2015
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(12 citation statements)
references
References 21 publications
0
10
0
1
Order By: Relevance
“…A 2x20 kDa mPEG moiety was coupled to the N‐terminus of PTH(1‐34) via a nonhydrolyzable 6‐mercaptohexanoic acid linker to investigate the level of PTH 1 receptor (PTH1R) activity after PEGylation. The residual bioactivity of this permanently PEGylated PTH(1‐34) conjugate was determined in HEK293 cells overexpressing PTH1R . The activity of TransCon PTH was low, with essentially no biological potency compared with a PTH(1‐34) reference sample.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…A 2x20 kDa mPEG moiety was coupled to the N‐terminus of PTH(1‐34) via a nonhydrolyzable 6‐mercaptohexanoic acid linker to investigate the level of PTH 1 receptor (PTH1R) activity after PEGylation. The residual bioactivity of this permanently PEGylated PTH(1‐34) conjugate was determined in HEK293 cells overexpressing PTH1R . The activity of TransCon PTH was low, with essentially no biological potency compared with a PTH(1‐34) reference sample.…”
Section: Resultsmentioning
confidence: 99%
“…04/200). The assay is a cell‐based potency assay for PTH concentration‐dependent cyclic adenosine monophosphate (cAMP) production in HEK293 cells overexpressing PTH1R as described by Hohenstein and colleagues (Bioassay ‐ Labor für Biologische Analytik GmbH, Heidelberg, Germany) . The activity of released PTH(1‐34) was determined after incubation of TransCon PTH in aqueous buffer at pH 10.1 and 5°C for 3 days.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…CV index obtained using 3 series of the sensibilized erythrocytes received in various experimental days from different animals. CV index should not exceed 25% for cell methods [12]. CV should not exceed 11.5% for different erythrocytes series (figure 4).…”
Section: правильность разработанного метода (Accuracy) оценивали по фmentioning
confidence: 97%
“…Устойчивость метода оценивали по ва-риабельности значений IC 50 для одной серии препарата, по показателю CV, ис-пользуя 3 серии сенсибилизированных эритроцитов, полученных в разные экспе-риментальные дни от разных животных. Для клеточных методов показатель CV не должен превышать 25.0% [12]. В экспери-ментах CV для разных партий эритроци-тов составило не более 11.5% (рис.…”
Section: правильность разработанного метода (Accuracy) оценивали по фunclassified