2008
DOI: 10.1016/j.talanta.2008.04.058
|View full text |Cite
|
Sign up to set email alerts
|

Development and validation of reversed phase liquid chromatographic method utilizing ultraviolet detection for quantification of irinotecan (CPT-11) and its active metabolite, SN-38, in rat plasma and bile samples: Application to pharmacokinetic studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
31
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 46 publications
(32 citation statements)
references
References 18 publications
1
31
0
Order By: Relevance
“…To determine the amount of SN-38 in the intestinal fluid, the methodology proposed by Bansal et al (2008) was followed with some modifications. Primary stock solutions for SN-38 (Sigma Aldrich) were prepared separately in DMSO at a concentration of 1 mg ml 21 .…”
Section: Methodsmentioning
confidence: 99%
“…To determine the amount of SN-38 in the intestinal fluid, the methodology proposed by Bansal et al (2008) was followed with some modifications. Primary stock solutions for SN-38 (Sigma Aldrich) were prepared separately in DMSO at a concentration of 1 mg ml 21 .…”
Section: Methodsmentioning
confidence: 99%
“…Theo btained LOD value for the anticancer drug Flu (1.55 10 À8 M) usingS WCASV at aP GE is substantially lower as compared with data reported previously at polymer film modified carbonp aste electrodes (1.81 10 À7 M) [41],ahangingm ercury drop electrode (1.90 10 À7 Ma nd 8.7 10 À8 M) [39],s pectrophotometric method (1.04 10 À6 Ma nd 4.77 10 À7 M) [32] and af low injection UV spectroscopy (4.34 10 À7 M) [33]. An improved detection limit was also achieved for the determination of the anticancer drug Irino (1.68 10 À9 M) at aP GE using the proposed procedure as compared with that obtained by HPLC( 2.41 10 À8 M) [20] and at polymethyleneb lue multiwalledc arbonn anotubesm odified glassy carbon electrode (2.14 10 À7 M) [43].I no rder to evaluate the accuracy and precision of the proposed method analysiso fF lu and Irino drugs at three levels of low,m oderate and high concentrations of the calibration curve was carried out in seven independent series at the same day (intra-day) and performed at the samel evel on seven different days (inter-day). Ther esults are summarized in Table 3.…”
Section: Validation Of the Swcasv Proceduref Or Trace Concentrations mentioning
confidence: 85%
“…Method was found to be selective, linear (R 2 ≈0.999), accurate (recovery ± 15 %) and precise (<5 % C.V.) in the selected concentration ranges for both the analytes. The quantification limit for irinotecan was 40 ng ml -1 and for SN-38 was 25 ng ml -1 [6].…”
Section: Analytical Assay Proceduresmentioning
confidence: 89%
“…The concentrations of irinotecan and SN-38 in plasma were determined using high performance liquid chromatographic (HPLC) method using ultraviolet detection (λ max = 254 nm, 380 nm) as described previously [6]. The sample pre-treatment from plasma involved a single protein precipitation step with cold acetonitrile.…”
Section: Analytical Assay Proceduresmentioning
confidence: 99%