2016
DOI: 10.1002/elan.201500411
|View full text |Cite
|
Sign up to set email alerts
|

Development of a Biosensor Based on Phosphotriesterase and n‐Channel ISFET for Detection of Pesticides

Abstract: A biosensor for the direct determination of organophosphorus pesticides (OPs) is described. It utilizes an ion‐selective field‐effect transistor and phosphotriesterase enzyme (PTE), which provides cleavage of OPs. The sensitivity of the biosensor was increased after PTE immobilization on the surface of the transistor. Packaging of the integrated circuit and creation of a microfluidic system for analyte delivery stabilized the signal. This system was able to detect 0.1 µM paraoxon and 0.5 µM parathion and methy… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 44 publications
0
18
0
Order By: Relevance
“…Moreover, the techniques require trained technicians to perform the analysis competently [41]. Thus, portable and specific enzymatic biosensors (especially for use in field OP monitoring), with high selectivity and sensitivity, would be very beneficial [42,43].…”
Section: Biosensorsmentioning
confidence: 99%
See 2 more Smart Citations
“…Moreover, the techniques require trained technicians to perform the analysis competently [41]. Thus, portable and specific enzymatic biosensors (especially for use in field OP monitoring), with high selectivity and sensitivity, would be very beneficial [42,43].…”
Section: Biosensorsmentioning
confidence: 99%
“…In enzymatic biosensing of OP compounds, the detection is based on either their inhibition of AChE or the hydrolysis process by the OP hydrolysis enzyme [42,43]. Detection using an inhibition-based sensor has been reported to have a high sensitivity and is capable of ultralow OP detection [42,44].…”
Section: Biosensorsmentioning
confidence: 99%
See 1 more Smart Citation
“…Kinetic measurements were performed at room temperature for 4 h, and the increase in absorbance at 650 nm was recorded. The measurement of nitroreductase activity using an ISFET was performed according to a method previously described [18], using a semiconductor device parameter analyzer (Agilent B1500A, Santa Clara, CA, USA) and a probe station (CascadeMicrotech PM5, Beaverton, OR, USA) operated by the Agilent VEE Pro software (Version A.04.20).…”
Section: Synthesis and Characterization Of Bocapsmentioning
confidence: 99%
“…Andrianova et al used a microfluidic device to deliver an analyte to a CMOS‐compatible n‐channel ISFET, which was able to detect the presence of organophosphorus pesticides. The pesticides were immobilized on the surface of ISFETs and a phosphodiesterase enzyme was used to enhance sensitivity . Demircan et al designed a label‐free LOC detection system that integrated DEP and CMOS imaging for leukemia cell detection .…”
Section: Applications Of Cmos Based Microfluidic Devicesmentioning
confidence: 99%