1992
DOI: 10.1109/10.135548
|View full text |Cite
|
Sign up to set email alerts
|

Development of a medical fiber-optic pH sensor based on optical absorption

Abstract: A new fiber-optic pH sensor system has been developed. The sensor uses an absorbtive indicator compound with a long wave-length absorption peak near 625 nm; change in absorption over the pH range 6.8 to 7.8 is reasonably linear. The sensor is interrogated by a pulsed, red LED. Return light signal is split into short and long wave-length components with a dichroic mirror; the respective signals are detected by photodiodes, and their photocurrents are used to form a ratiometric output signal. In laboratory tests… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0
2

Year Published

2004
2004
2022
2022

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 56 publications
(20 citation statements)
references
References 14 publications
0
18
0
2
Order By: Relevance
“…pH 10 measurements were performed in continuous flow mode using fiber-optic light guides aligned to the device using an in-house made cell. The main advantage of these sensors is that no reagent indicator is needed to measure the pH, because the PAni acts as the indicator itself, reducing the complexity of pH detection 15 inside microchannels. The functionalisation process is easy and highly reproducible from microdevice to microdevice and over the whole microchannel length.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…pH 10 measurements were performed in continuous flow mode using fiber-optic light guides aligned to the device using an in-house made cell. The main advantage of these sensors is that no reagent indicator is needed to measure the pH, because the PAni acts as the indicator itself, reducing the complexity of pH detection 15 inside microchannels. The functionalisation process is easy and highly reproducible from microdevice to microdevice and over the whole microchannel length.…”
Section: Discussionmentioning
confidence: 99%
“…Microfluidic device fabrication 15 The fabrication of the master mold was carried out using a laser ablation system-excimer/CO 2 laser (Optec Laser Micromachining Systems, Belgium) by cutting the microfluidic structures in a 50 µm double-sided pressure sensitive adhesive film, PSA, (AR8890, Adhesives Research, Ireland) and pasting 20 one of the PSA sides to a petri dish 47 .…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations