2004
DOI: 10.1016/j.aca.2003.09.008
|View full text |Cite
|
Sign up to set email alerts
|

Development of a new fluorimetric bulk optode membrane based on 2,5-thiophenylbis(5-tert-butyl-1,3-benzexazole) for nickel(II) ions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
41
0

Year Published

2006
2006
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 74 publications
(41 citation statements)
references
References 33 publications
0
41
0
Order By: Relevance
“…In recent years, we have prepared a number of fluorimetric bulk optode membranes based on novel fluoroionophores for elective determination of traces of Ag + [12], Ni 2+ [14], Cu 2+ [15] and Hg 2+ [20] ions. In this work, we found that the strong fluorescence of 7-[(5-chloro-8-hydroxy-7-quinolinyl)methyl]-5,6,7,8,9,10-hexahydro-2H-1,13,4,7,10-benzodioxatriazacyclopentadecine-3,11(4H,12H)-dione (L) in a PVC membrane ( ex = 345 nm and em = 516 nm) quenched considerably, and in a selective manner, upon complexation with Co 2+ ion.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In recent years, we have prepared a number of fluorimetric bulk optode membranes based on novel fluoroionophores for elective determination of traces of Ag + [12], Ni 2+ [14], Cu 2+ [15] and Hg 2+ [20] ions. In this work, we found that the strong fluorescence of 7-[(5-chloro-8-hydroxy-7-quinolinyl)methyl]-5,6,7,8,9,10-hexahydro-2H-1,13,4,7,10-benzodioxatriazacyclopentadecine-3,11(4H,12H)-dione (L) in a PVC membrane ( ex = 345 nm and em = 516 nm) quenched considerably, and in a selective manner, upon complexation with Co 2+ ion.…”
Section: Introductionmentioning
confidence: 99%
“…The recognition process by fluoroionophores takes place by their ionophore part which is then converted to a change in the fluorophore's signal, brought about by the perturbation of such photoinduced processes as energy transfer, charge transfer, electron transfer, formation or disappearance of eximers and exciplexes [6,12,13]. In recent years, several fluorescence sensors have been developed for the detection of transition and heavy metal ions including Ag + [12], Ni 2+ [14], Cu 2+ [15,16], Pb 2+ [17,18], Cd 2+ [19], Hg 2+ [20,21] and Fe 3+ [22,23].…”
Section: Introductionmentioning
confidence: 99%
“…This high selectivity was attributed to the formation of a new adduct between the Fe(III) in the center of the complex and the thiocyanate ion. 12 Thus, based on this selectivity the FepytBrsal compound is expected to act as a selective chromoionophore in the preparation of a PVC-based ion-selective optode for SCN -.…”
Section: Solution Studiesmentioning
confidence: 99%
“…Optodes are generally used in combination with inexpensive spectrophotometic or spectroflourometic techniques to provide simple and fast determination methods with enhanced selectivity and low detection limits [9][10][11][12][13]. , Hg 2+ and Cu 2+ [14][15][16][17][18][19][20][21][22]. Use of transparent triacetyl cellulose and agarose membranes as supports for preparation of covalently immobilized optical sensors for some ions determination were reported by different laboratories.…”
Section: Introductionmentioning
confidence: 99%