2022
DOI: 10.1016/j.bios.2021.113768
|View full text |Cite
|
Sign up to set email alerts
|

Development of a peptide aptamer pair-linked rapid fluorescent diagnostic system for Zika virus detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 36 publications
0
9
0
Order By: Relevance
“…The commercial H5-specific RDT kit commonly used in Korea (Catalog Number: RG1505MH, Bionote) also failed to detect H5 HPAIVs within the 2.3.4.4b subclade ( Figure S10 ). In the present study, we developed two novel mAbs against the 2.3.4.4b subclade and conjugated these mAbs to Eu NPs, which are well-known fluorescence materials employed to improve the sensitivity of RDT kits [ 47 , 48 , 49 , 50 ]. Thus, our FICT assay obtained an LoD of 10 3.9 EID50/test ( Figure S11 ) for the detection of H5 2.3.4.4b viruses, which was ~7.9-fold higher than that reported by Nguyen et al (2017), and 32-fold higher than that of the colloidal gold-based RDT kit using the same pair of mAbs.…”
Section: Discussionmentioning
confidence: 99%
“…The commercial H5-specific RDT kit commonly used in Korea (Catalog Number: RG1505MH, Bionote) also failed to detect H5 HPAIVs within the 2.3.4.4b subclade ( Figure S10 ). In the present study, we developed two novel mAbs against the 2.3.4.4b subclade and conjugated these mAbs to Eu NPs, which are well-known fluorescence materials employed to improve the sensitivity of RDT kits [ 47 , 48 , 49 , 50 ]. Thus, our FICT assay obtained an LoD of 10 3.9 EID50/test ( Figure S11 ) for the detection of H5 2.3.4.4b viruses, which was ~7.9-fold higher than that reported by Nguyen et al (2017), and 32-fold higher than that of the colloidal gold-based RDT kit using the same pair of mAbs.…”
Section: Discussionmentioning
confidence: 99%
“…To identify ZIKV, Nguyen et al created a new biosensor [149] . A peptide aptamers pair (PAP) were used to create an antibody-free lateral FICT.…”
Section: Zika Detectionmentioning
confidence: 99%
“…To overcome the disadvantages of cross-reactivity, long preparation cycles, and the high costs of antibodies, a peptide pair-based flow immunochromatographic test strip (FICT) assay targeting the ZIKV E protein were established. 72 Here, peptide aptamer B2.33 was directly coated to the detection line of the nitrocellulose (NC) membrane as the capture peptide and europium nanoparticle-linked peptide aptamer P6.1 in the conjugate pad as the FICT detector (Fig. 2B).…”
Section: Research Advances In the Diagnosis Of Infectious Diseasesmentioning
confidence: 99%