2021
DOI: 10.1016/j.mssp.2020.105337
|View full text |Cite
|
Sign up to set email alerts
|

Development of amperometric biosensors using VO2/GOx films for detection of glucose

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 31 publications
0
4
0
Order By: Relevance
“…The feasibility of synthesizing polyFA membranes in aqueous media with acidic, alkaline, and neutral pH was also demonstrated, increasing the potential of polymer membranes for the development of biosensing membranes. Furthermore, for the design of glucose biosensors, substances such as p-coumaric acid (p-CA) and vanadium dioxide (VO 2 ) can be used [ 46 , 47 ].…”
Section: Enzymatic Electrochemical Biosensors For Food Bioprocess Mon...mentioning
confidence: 99%
“…The feasibility of synthesizing polyFA membranes in aqueous media with acidic, alkaline, and neutral pH was also demonstrated, increasing the potential of polymer membranes for the development of biosensing membranes. Furthermore, for the design of glucose biosensors, substances such as p-coumaric acid (p-CA) and vanadium dioxide (VO 2 ) can be used [ 46 , 47 ].…”
Section: Enzymatic Electrochemical Biosensors For Food Bioprocess Mon...mentioning
confidence: 99%
“…In addition to phase change characteristics, vanadium dioxide can also be electrochemically oxidized, can be used as an electrochemically stable material in oxidation and reduction process, and it shows great flexibility in inorganic networks for chemical detection and application in the field of chemical sensors. For example, E.M. Guerra's team used VO 2 thin film to modify the electrode to make the electrode surface have high electrochemical porosity, so that the sensor showed superior sensitivity and a large electrochemical activity region, and achieved 61.5 mV/pH (pH = 5-8) [160] and 33.9 mV/pH (pH = 4-10) [161] sensitivity in AZI and glucose sensor designs, respectively.…”
Section: Sensorsmentioning
confidence: 99%
“…The strategy was innovative but complex, raising production costs. 118 VO 2 has also been investigated for metasurface device applications such as biosensing, 120 planar lenses, 121 absorbers surfaces, 122,123 radiative thermal rectifiers, 124 holograms, 125 wave plates, 126 and more. In the past, adjustable metasurfaces were made to control only a single variable, such as phase or amplitude.…”
Section: Possible Application Of Vo 2 Thin Filmsmentioning
confidence: 99%