2022
DOI: 10.1016/j.ijpharm.2022.122323
|View full text |Cite
|
Sign up to set email alerts
|

Development of chloramphenicol whey protein-based microparticles incorporated into thermoresponsive in situ hydrogels for improved wound healing treatment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 59 publications
2
4
0
Order By: Relevance
“…HPC is known to have a lower viscosity and slow hydration, and this is thought to be related to its adhesive ability [39] In contrast to HPMC, which in this study showed higher viscosity, resulting in higher bioadhesive strength. The number of hydrogen bonds formed is thought to affect the inherent properties of HPMC [40,41]. Furthermore, formula G4a, which did not contain bioadhesive polymers, still showed adhesion; this proves that poloxamer also has an adhesive effect as stated in previous studies [42],…”
Section: Bioadhesion Strength Studysupporting
confidence: 66%
See 1 more Smart Citation
“…HPC is known to have a lower viscosity and slow hydration, and this is thought to be related to its adhesive ability [39] In contrast to HPMC, which in this study showed higher viscosity, resulting in higher bioadhesive strength. The number of hydrogen bonds formed is thought to affect the inherent properties of HPMC [40,41]. Furthermore, formula G4a, which did not contain bioadhesive polymers, still showed adhesion; this proves that poloxamer also has an adhesive effect as stated in previous studies [42],…”
Section: Bioadhesion Strength Studysupporting
confidence: 66%
“…Furthermore, another glass object was placed on top of the gel and given a load of 500 g and kept for 5 minutes. The diameter of the gel was measured as the spreadability of the gel [22,23] 2.9.6. Drug content analysis…”
Section: Spreadabilitymentioning
confidence: 99%
“…The test tube was observed visually every 1°C temperature increase. The gelation temperature recorded was the temperature at which the gel did not move when the tube was inverted to 90° [24].…”
Section: Gelation Temperature Measurementmentioning
confidence: 99%
“…The pH of the thermosensitive gel was measured using a pH-meter at room temperature by inserting the tip of the electrode into the gel and the results were recorded after 2 minutes of observation [24].…”
Section: Ph Measurementmentioning
confidence: 99%
See 1 more Smart Citation