2018
DOI: 10.1016/s1872-2040(17)61078-8
|View full text |Cite
|
Sign up to set email alerts
|

Development of Dipolar Proton Transfer Reaction Mass Spectrometer for Real-time Monitoring of Volatile Organic Compounds in Ambient Air

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…332,350 Recently, a novel dipolar proton transfer reaction mass spectrometer (DP-PTR-MS) for real-time and on-line monitoring of atmospheric VOCs has been developed. 351 Compared with conventional PTR-MS with one kind of reagent ion, DP-PTR-MS had three kinds of reagent ions, H 3 O + , OH − and (CH 3 ) 2 COH + , which could be switched according to the actual measurement need. DP-PTR-MS improved the qualitative ability and expanded the detection range effectively.…”
Section: Instrumental Analytical Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…332,350 Recently, a novel dipolar proton transfer reaction mass spectrometer (DP-PTR-MS) for real-time and on-line monitoring of atmospheric VOCs has been developed. 351 Compared with conventional PTR-MS with one kind of reagent ion, DP-PTR-MS had three kinds of reagent ions, H 3 O + , OH − and (CH 3 ) 2 COH + , which could be switched according to the actual measurement need. DP-PTR-MS improved the qualitative ability and expanded the detection range effectively.…”
Section: Instrumental Analytical Methodsmentioning
confidence: 99%
“…332,350 Recently, a novel dipolar proton transfer reaction mass spectrometer (DP-PTR-MS) for real-time and on-line monitoring of atmospheric VOCs has been developed. 351 Selected ion ow tube-mass spectrometry (SIFT-MS) is another powerful tool based on chemical ionization, which has been widely used for the rapid and sensitive real-time detection and quantication of volatile organic compounds. [352][353][354][355] The principle of the SIFT-MS technique has been fully described in ref.…”
Section: Reviewmentioning
confidence: 99%
“…Recently, Proton transfer reaction (PTR) ion source has attracted people's attention, which will be an important technique to detect trace amounts of VOCs in atmospheric environment [30][31][32]. PTR-MS can detect the absolute concentration of VOCs within several minutes and consequently the real-time monitoring VOCs changes [33].…”
Section: Ion Sourcementioning
confidence: 99%