2010
DOI: 10.1364/ao.49.000c95
|View full text |Cite
|
Sign up to set email alerts
|

Development of microwave-enhanced spark-induced breakdown spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
20
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 52 publications
(20 citation statements)
references
References 15 publications
0
20
0
Order By: Relevance
“…A secondary excitation of the laser-induced plasma can enhance the optical signals and improve the detection sensitivity. Techniques employed for secondary excitation in LIBS include double laser pulses (St-Onge et al , 1998;Babushok et al , 2006;Ctvrtn í kova et al , 2008;Windom and Hahn, 2009;Viskup et al , 2010;Heilbrunner et al , 2012), electric spark discharges (Chen et al , 2010;Kexue et al , 2010), and radiofrequency (Bian et al , 2005;Deng et al , 2010;Pedarnig et al , 2011) and microwave (Ikeda et al , 2010;Liu et al , 2010) radiation. …”
Section: Multi-element Detectionmentioning
confidence: 99%
“…A secondary excitation of the laser-induced plasma can enhance the optical signals and improve the detection sensitivity. Techniques employed for secondary excitation in LIBS include double laser pulses (St-Onge et al , 1998;Babushok et al , 2006;Ctvrtn í kova et al , 2008;Windom and Hahn, 2009;Viskup et al , 2010;Heilbrunner et al , 2012), electric spark discharges (Chen et al , 2010;Kexue et al , 2010), and radiofrequency (Bian et al , 2005;Deng et al , 2010;Pedarnig et al , 2011) and microwave (Ikeda et al , 2010;Liu et al , 2010) radiation. …”
Section: Multi-element Detectionmentioning
confidence: 99%
“…Kearton et al and Liu et al reported intensity enhance- ments obtained by using laser-assisted MW spectroscopy (LAMPS) [19,20]. Ikeda et al used MWs to extend the lifetime of plasma emission to the order of a millisecond [21]. However, these methods required the use of waveguides and microwave cavities.…”
Section: Introductionmentioning
confidence: 99%
“…Research and development efforts invested in the last two decades have yielded a number of enhanced LIBS techniques with excellent sensitivity and accuracy. [3][4][5][6] As the performance of LIBS evolves in laboratories, there is increasing focus on the development of portable LIBS instruments for use in the field as stand-off sensing tools for harsh or dangerous environments. [7][8][9] This has been hindered by the lack of compact, high efficiency, and highly reliable lasers that can produce plasmas with sufficient optical emission.…”
Section: Introductionmentioning
confidence: 99%