Fifth International Conference onElectronic Packaging Technology Proceedings, 2003. ICEPT2003. 2003
DOI: 10.1109/eptc.2003.1298690
|View full text |Cite
|
Sign up to set email alerts
|

Development of probing mark analysis model [IC testing]

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2007
2007
2015
2015

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 2 publications
0
7
0
Order By: Relevance
“…The results obtained from the simplified model for the scrub mark length are particularly inaccurate. In practice, this can be attributed to the use of the rigid-body rotation assumption in (5). Table V shows the optimized values of the needle design parameters for each of the four rows of the KX869TW probe card.…”
Section: Validation Of Optimization Resultsmentioning
confidence: 98%
See 1 more Smart Citation
“…The results obtained from the simplified model for the scrub mark length are particularly inaccurate. In practice, this can be attributed to the use of the rigid-body rotation assumption in (5). Table V shows the optimized values of the needle design parameters for each of the four rows of the KX869TW probe card.…”
Section: Validation Of Optimization Resultsmentioning
confidence: 98%
“…In most practical applications, the contact force should not exceed 2.5 gf/mil and the scrub mark should terminate at a point no closer than 5-8 μm from the pad boundary [1]. The literature contains many numerical and experimental investigations into the relationship between the contact force and the scrub mark length in the probe testing of aluminum pads using a single tungsten needle [2]- [5]. In general, the results show that the contact force and the scrub mark length both increase with an increasing overdrive level.…”
Section: Introductionmentioning
confidence: 99%
“…Several literatures (Bates, 1997;Comeau and Naduau, 1991;Chao et al, 2003;Liu and Shih, 2006) revealed that the contact force sensitivity is a function of the dimensions of probing needle, but none of them studied the effect of the geometric changes on the contact force and the forward displacement systematically. In this study, a finite element model of a cantilever needle was first constructed to simulate the stress distribution and the needle tip displacement during probing.…”
Section: Fig 1 -Epoxy Ring Probe Card For DVI Probing Test (Providedmentioning
confidence: 99%
“…Broz and Rincon (1999) proposed a contact theory of the probe tip and the weld pad, and discussed the effect of the temperature arising on contact resistance. Chao et al (2003) built a 3-D finite element model to simulate probe testing, and single probe experiments were performed in micro-tester. The relation between contact forces and overdrive of the probing mark were obtained.…”
Section: Introductionmentioning
confidence: 99%
“…In the literature, usually the authors analyze the bond pad failure with static modeling, results might be correlated with experimental results [5,6]. Some studies point out the dynamic deformation of contact phenomenon with explicit finite elements analysis and investigate the scrub mark on the die [7,8]. The reaction force and dynamic behavior of needle is simulated by Schmadlak and al., they observe dynamic effects during the first 100µs after the impact time but its magnitude remains low [9].…”
Section: Probing Simulationmentioning
confidence: 99%