2020
DOI: 10.1159/000505638
|View full text |Cite
|
Sign up to set email alerts
|

Dexamethasone Implant Migration through an Iris Coloboma

Abstract: Ozurdex ® 0.7 mg (dexamethasone 0.7 mg implant, Allergan, Dublin, Ireland), an intravitreal biodegradable implant, is indicated for cystoid macular edema due to various causes. One of its known and uncommon complications is implant migration to the anterior chamber, causing corneal edema that, in some cases, is irreversible. Reported risk factors for device migration are open or defective lens capsule and prior history of vitrectomy. We present a case of dexamethasone implant migration through a congenital iri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…However some other approaches prioritize minimization of contact between instruments and the implant in order to reduce the chance of breaking it into fragments [ 12 ]. These include use of BSS to direct flow through a corneal incision and out of the AC [ 4 , 10 ] and similarly a no-touch technique using viscoelastic to allow implant egression. In this no-touch technique, a corneal incision is made and the implant is positioned parallel to the incision’s axis.…”
Section: Discussionmentioning
confidence: 99%
“…However some other approaches prioritize minimization of contact between instruments and the implant in order to reduce the chance of breaking it into fragments [ 12 ]. These include use of BSS to direct flow through a corneal incision and out of the AC [ 4 , 10 ] and similarly a no-touch technique using viscoelastic to allow implant egression. In this no-touch technique, a corneal incision is made and the implant is positioned parallel to the incision’s axis.…”
Section: Discussionmentioning
confidence: 99%
“…This finding led the authors to conclude that a lens capsule defect or a history of PPV increases the chance of AC migration. Pseudophakia, 610 including posterior chamber intraocular lenses (PCIOL), anterior chamber intraocular lenses (ACIOL), 11,12 sulcus intraocular lenses, iris-fixated lenses, 57,13,14 scleral-fixated lenses, 12,1519 and glued IOLs, 20 have all been reported in cases of implant migration. Aphakia, 5,2126 prior iridectomies, 6,12,20,26,27 congenital iris coloboma, 10 posterior capsule violation during prior surgeries or following posterior capsulotomies, 5,7,13,27 and weak zonules 9,28 are other features frequently noted in these cases.…”
Section: Discussionmentioning
confidence: 99%
“…Pseudophakia, 610 including posterior chamber intraocular lenses (PCIOL), anterior chamber intraocular lenses (ACIOL), 11,12 sulcus intraocular lenses, iris-fixated lenses, 57,13,14 scleral-fixated lenses, 12,1519 and glued IOLs, 20 have all been reported in cases of implant migration. Aphakia, 5,2126 prior iridectomies, 6,12,20,26,27 congenital iris coloboma, 10 posterior capsule violation during prior surgeries or following posterior capsulotomies, 5,7,13,27 and weak zonules 9,28 are other features frequently noted in these cases. Other alterations to the natural lens or iris anatomy may place patients at higher risk of implant migration due to the presence of additional pathways for the implant to travel.…”
Section: Discussionmentioning
confidence: 99%