Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors

Abstract: Partial discharges (PD) measurement provides valuable information for the condition assessment of the insulation status of high-voltage (HV) electrical installations. During the last three decades, several PD sensors and measuring techniques have been developed to perform accurate diagnostics when PD measurements are carried out on-site and on-line. For utilities, the most attractive characteristics of on-line measurements are that once the sensors are installed in the grid, the electrical service is uninterru… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
2
2

Relationship

1
9

Authors

Journals

citations
Cited by 26 publications
(14 citation statements)
references
References 23 publications
0
14
0
Order By: Relevance
“…Thus, in order to evaluate properly the separation method developed, the three PD sources were intentionally placed close to the HFCT sensor, as per Figure 7. It is important to indicate that if the PD sources are not in the same location, the use of previous diagnosis tools that analyse the pulses' amplitude, polarity, frequency or time of flight enable a first separation of sources usually without many difficulties [27,28].…”
Section: Hv Equipment and Measuring Instrumentmentioning
confidence: 99%
“…Thus, in order to evaluate properly the separation method developed, the three PD sources were intentionally placed close to the HFCT sensor, as per Figure 7. It is important to indicate that if the PD sources are not in the same location, the use of previous diagnosis tools that analyse the pulses' amplitude, polarity, frequency or time of flight enable a first separation of sources usually without many difficulties [27,28].…”
Section: Hv Equipment and Measuring Instrumentmentioning
confidence: 99%
“…Several PD detection methods have been developed according to the physical properties of the insulation system, which accompany PD activity, such as current pulse method [21], ultrasonic detection, ultra-high-frequency (UHF) detection, and the optical method [22,23]. However, the lower frequency limit of conventional pulse current methods is close to that in the high-frequency transformer, the ultrasonic detection is not sensitive enough because of the complex acoustic impedance, the UHF signals are affected by communication signals, and there is still no known experience with optical measurements in this kind of electrical equipment.…”
Section: Partial Discharge Measurement Setupmentioning
confidence: 99%
“…Various electrical, mechanical, and chemical methods have been used to detect PDs in GISs [7,8]. Some existing electrical methods use ultra-high frequency (UHF) sensors [9][10][11][12][13], while sound measurement methods use acoustic sensors [14,15] and chemical methods use dissolved gas analysis [16,17]. In this study, an electrical method that employs a UHF sensor is used for the PD measurement system.…”
Section: Introductionmentioning
confidence: 99%