2019
DOI: 10.1016/j.ijcard.2018.09.010
|View full text |Cite
|
Sign up to set email alerts
|

Diagnostic accuracy of coronary CT angiography performed in 100 consecutive patients with coronary stents using a whole-organ high-definition CT scanner

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
15
0
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 21 publications
1
15
0
2
Order By: Relevance
“…Cardiac CT offers an accurate anatomical evaluation of CAD comparable to ICA 5 . For this reason, coronary CT angiography has rapidly become an alternative to ICA for CAD assessment and the new generation scanners are now considered to have high diagnostic performance for detection of significant coronary stenosis in different populations 2 . The low cost and high sensitivity of cardiac CT makes it the non-invasive test of choice in the evaluation of stable angina 2 .…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Cardiac CT offers an accurate anatomical evaluation of CAD comparable to ICA 5 . For this reason, coronary CT angiography has rapidly become an alternative to ICA for CAD assessment and the new generation scanners are now considered to have high diagnostic performance for detection of significant coronary stenosis in different populations 2 . The low cost and high sensitivity of cardiac CT makes it the non-invasive test of choice in the evaluation of stable angina 2 .…”
Section: Discussionmentioning
confidence: 99%
“…For this reason, coronary CT angiography has rapidly become an alternative to ICA for CAD assessment and the new generation scanners are now considered to have high diagnostic performance for detection of significant coronary stenosis in different populations 2 . The low cost and high sensitivity of cardiac CT makes it the non-invasive test of choice in the evaluation of stable angina 2 . This has now been ratified in national guidelines with National Institute for Health and Care Excellences (NICE) recommending cardiac CT as the first-line investigation for all patients presenting with angina pectoris in whom CAD is therefore suspected 1 .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Sei Komatsu 1, 2) * , Satoru Takahashi 1) , Chikao Yutani 2,3,4) , Tomoki Ohara 1) , Mitsuhiko Takewa 1) , Atsushi Hirayama 2,5) and Kazuhisa Kodama 1,2,5) Aortic angioscopy using non-obstructive general angioscopy (NOGA) is a novel, video-based technique that allows visualization of the inner aorta. Dual infusion method improves the visual field and the use of an Ikari-L guiding catheter allows easy access to the aorta, enabling NOGA of not only the coronary artery but also aorta.…”
Section: Non-obstructive General Angioscopymentioning
confidence: 99%
“…However, their representation of atherosclerosis is partial and indirect 2,3) . CT angiography (CTA) has limited spatial resolution, up to 230 μm of the next-generation CT 5,6) . CTA may provide static grayscale images and even four-dimensional images.…”
Section: Introductionmentioning
confidence: 99%