Abstract: AimTo evaluate the applicability of imaging devices (spectral-domain optical coherence tomography (Cirrus SD-OCT), scanning laser polarimetry (GDx) and scanning laser ophthalmoscopy (Heidelberg Retinal Tomograph, HRT3)) for glaucoma screening in a middle-aged unselected population.MethodsParticipants of the population-based Northern Finland Birth Cohort Eye Study, aged 45 to 49 years, underwent a comprehensive eye examination including modern imaging with five methods (retinal nerve fibre layer (RNFL) and macu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
32
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(33 citation statements)
references
References 22 publications
0
32
0
1
Order By: Relevance
“…The performance of both enface and conventional indices might not necessarily be representative of clinical settings aiming to diagnose the earliest glaucoma cases, in which conventional OCT analyses perform more poorly. [55][56][57][58] Despite this limitation, some of the enface parameters presented hold promise for early glaucoma detection. For instance, sectors-average first gap discriminated glaucoma perfectly in this sample, warranting further exploration of the use of this parameter in glaucoma diagnosis.…”
Section: Discussionmentioning
confidence: 99%
“…The performance of both enface and conventional indices might not necessarily be representative of clinical settings aiming to diagnose the earliest glaucoma cases, in which conventional OCT analyses perform more poorly. [55][56][57][58] Despite this limitation, some of the enface parameters presented hold promise for early glaucoma detection. For instance, sectors-average first gap discriminated glaucoma perfectly in this sample, warranting further exploration of the use of this parameter in glaucoma diagnosis.…”
Section: Discussionmentioning
confidence: 99%
“…not reaching the chin rest) or in a supine position, e.g., under general anaesthesia [ 5 ]. Similarly to reports in adults though [ 13 ], the moderate sensitivity of OCT measurements of the pRNFL make it unsuitable for usage as a standalone screening or diagnostic method in childhood glaucoma. In summary, due to the fact that most diagnostically reliable SLP parameters are unavailable in children, OCT seems the more accurate method for pRNFL thickness measurements in paediatric glaucoma.…”
Section: Discussionmentioning
confidence: 99%
“…Observations of sensitivity and specificity confirm these findings: at fixed specificities of 80%, 90%, and 95%, sensitivity was markedly lower for SLP measurements compared to OCT. Previously, in adults, a good glaucoma diagnostic performance (as by AUC calculation) was observed for pRNFL measurements by SLP [8,34] as well as OCT [34] and both methods have been reviewed as equivalent in a Cochrane report [19] as well as in a recent large cohort study [13] when considering best performing parameters. In particular, SLP parameters with the highest AUC are the nerve fibre indicator (NFI) and the TNSIT score, which are both calculated values without an OCT surrogate.…”
Section: The Diagnostic Performance Of Oct Assessed Prnflmentioning
confidence: 99%
See 1 more Smart Citation
“…Optical coherence tomography (OCT), introduced by Huang et al in 1991 for the first time, has become an invaluable tool for early diagnosis and follow-up of cases of neurodegenerative disorders like glaucoma, optic neuritis, multiple sclerosis, etc. [1][2][3]. It allows for non-invasive micrometer resolution of cross-sectional images of the retina in human beings [4].…”
Section: Introductionmentioning
confidence: 99%