Die Bestimmung der p-Aminobenzoesäure mit Fluram ® im Urin nach Durchführung des Pankreasfunktionstests mit Bentiromid

Abstract: Zusammenfassung: Es wird ein Verfahren vorgestellt, das bei der Durchführung des Pankreas-Funktions-Tests die Ausscheidung von p-Arninobenzoesäure in Urin nach Verabreichung von Bentiromid (N-Benzoyl-£-tyrosyl-p-aminobenzoesäure) mit (Fluram) (Fluorescamin) bestimmt. Das Verfahren liefert zuverlässige Werte und erlaubt eine einfache faktorielle Berechnung der ausgeschiedenen Menge anp-Aminobenzoesäure. The Use of Fluram R for the determination ofp-aminobenzoic acid in test for pancreatic function with bentirom… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1987
1987
1998
1998

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Para ‐aminobenzoic acid in urine . We determined para ‐aminobenzoic acid spectrophotometrically with fluorescamine (Roche, 071088) as described previously [19]. Addition of 200 μg of para ‐aminobenzoic acid to 1 mL of urine yielded a recovery of 96% ( n = 2).…”
Section: Methodsmentioning
confidence: 99%
“…Para ‐aminobenzoic acid in urine . We determined para ‐aminobenzoic acid spectrophotometrically with fluorescamine (Roche, 071088) as described previously [19]. Addition of 200 μg of para ‐aminobenzoic acid to 1 mL of urine yielded a recovery of 96% ( n = 2).…”
Section: Methodsmentioning
confidence: 99%
“…Para-aminobenzoic acid in urine. We determined paraaminobenzoic acid spectrophotometrically with fluorescamine (Roche, 071088) as described previously [19]. Addition of 200 g of para-aminobenzoic acid to 1 mL of urine yielded a recovery of 96% (n ϭ 2).…”
Section: Cafestol and Kahweol In Coffee And Gastrointestinal Fluidsmentioning
confidence: 99%
“…This obviated the necessity of prior toxicologic studies. (4) In our HPLC assay for PABA,' PAS was detected also with a retention time suitable for accurate quantification of both compounds. As reported here for five healthy volunteers day to day variations in PAS excretion were not always negligible, confirming the day to day variations in PABA excretion reported by Kay et al 2 As a consequence, in one case a difference of 0-22 was found between PABA/PAS ratio and PABA excretion index (Table), although in the other case both parameters corresponded very well.…”
Section: Discussionmentioning
confidence: 97%