2016
DOI: 10.1016/j.proeng.2016.11.779
|View full text |Cite
|
Sign up to set email alerts
|

Differentiated Drying of the Mixtures Colloidal Components Used in the Construction of Underground Infrastructure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
9
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 1 publication
0
9
0
Order By: Relevance
“…In the drying process, the amount of moisture in the grains decreases, in connection with which, the mass of one grains and its moisture content decreases [4,7,8]:…”
Section: Theoretical Backgroundmentioning
confidence: 99%
See 2 more Smart Citations
“…In the drying process, the amount of moisture in the grains decreases, in connection with which, the mass of one grains and its moisture content decreases [4,7,8]:…”
Section: Theoretical Backgroundmentioning
confidence: 99%
“…The influence of the temperatures of the agent and the grains on the coefficient of moist air B WA is reflected on the response surface ( Figure 2), from which it can be seen that in the heating zone the coefficient B WA , and hence the heat transfer coefficient α, is more important than in the cooling zone. Assuming a uniform change in the temperature of the layer at various points, a heat balance system for the heating and cooling process is obtained for natural convection [1,2,3,7]: P= ± 6.28 · π · 10 -3 · (2 · l · a / (l + a)) -0.625 · (5 · a + 6 · b) / 60 · (1 -(5 · a + 6 · b)/20) · dT g 9/8 · X C ;…”
Section: Theoretical Backgroundmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, having the ability to control the concentration of dust, it is possible to monitor the concentration of CFU. To solve the above-mentioned problem, a system of automated regulation of microclimate parameters in a cattlebreeding room was developed on the basis of the Arduino hardware platform (Figure 3), which includes a controller unit, which receives signals from gassing and dust sensors, and temperature and humidity sensors for internal and external air , electric drives of air dampers, the electric drive of the fan, a control system for the parameters of the corona discharge system of the electrostatic precipitator [7,8,9].…”
mentioning
confidence: 99%
“…Let us determine the amount i of harmfulness in the room using the formula (13). For this room, according to known methods [5,7], DMEF was calculated and modeled with the following parameters. The efficiency of air purification: from dust and aerosol particles -95%, from microorganisms -77%, from ammonia -84%, from hydrogen sulphide -50%.…”
mentioning
confidence: 99%