2021
DOI: 10.1016/j.mri.2021.09.007
|View full text |Cite
|
Sign up to set email alerts
|

Diffusion weighted imaging for evaluation of breast lesions: Comparison between high b-value single-shot and routine readout-segmented sequences at 3 T

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 26 publications
0
5
0
Order By: Relevance
“…SyDWIs with high b values showed better SNR and less image distortion than scanned high-b-value DWIs. They also showed a higher contrast-to-noise ratio (CNR) between the lesions and the background compared to low-b-value DWIs, improving the efficiency of lesion detection in research of systemic malignant tumors, prostate cancer, breast cancer, and liver metastasis [5,[23][24][25]. SyDWI with b = 1500 s/mm 2 had higher image quality and detection rate in the diagnosis of pancreatic cancer than the real scanned DWIs with a high b value.…”
Section: Introductionmentioning
confidence: 99%
“…SyDWIs with high b values showed better SNR and less image distortion than scanned high-b-value DWIs. They also showed a higher contrast-to-noise ratio (CNR) between the lesions and the background compared to low-b-value DWIs, improving the efficiency of lesion detection in research of systemic malignant tumors, prostate cancer, breast cancer, and liver metastasis [5,[23][24][25]. SyDWI with b = 1500 s/mm 2 had higher image quality and detection rate in the diagnosis of pancreatic cancer than the real scanned DWIs with a high b value.…”
Section: Introductionmentioning
confidence: 99%
“…Lower SNR in ss-EPI images with a high b-value (1000 sec/mm 2 ) might induce inaccuracy of quantitative parameter values. 33 Furthermore, we attempted to explore the potential factors that affect the reproducibility of quantitative parameters in this study. Higher variability of quantitative parameters in both intraobserver and interobserver reproducibility is likely related to the tumor heterogeneity.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, the accuracy of quantitative parameters can be affected by imaging SNR. Lower SNR in ss‐EPI images with a high b‐value (1000 sec/mm 2 ) might induce inaccuracy of quantitative parameter values 33 …”
Section: Discussionmentioning
confidence: 99%
“…However, obtaining multi-parametric MRI makes the examination costly from financial and time considerations, thus making acquisition of an exhaustive multiparametric MRI protocol less optimal [8,9]. Currently, MRI-based breast cancer screening is highly valued by clinicians and researchers [10,11,12,13,14]. Typically, only T1-weighted pre-and post-contrast MRI and DWI or T2 are included in the screening protocols, and while some abbreviated MRI protocols have also explored obtaining more MRI parameters, this is time-consuming and costly [3,15,16,17,18].…”
Section: Introductionmentioning
confidence: 99%