2007
DOI: 10.5664/jcsm.26813
|View full text |Cite
|
Sign up to set email alerts
|

Digital Analysis and Technical Specifications

Abstract: and is the principal investigator on research managed by Baylor College of Medicine including contract research from Evotec, Neurogen, Sanofi-Aventis, GlaxoSmithKline, Merck, Takeda, NBI, Respironics, and Organon. Dr. Harsh is on the advisory board for Cephalon. Dr. Chervin is on the scientific advisory board of Pavad Medical and is a consultant for Alexa Pharmaceuticals. Mr. Butkov has financial interests in the School Of Clinical Polysomnography, Inc. and Synapse Media. Dr. Vitiello is on the speakers bureau… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
23
0
6

Year Published

2007
2007
2022
2022

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 82 publications
(30 citation statements)
references
References 119 publications
1
23
0
6
Order By: Relevance
“…Briefly, surface electrodes (3M Red dot; 3M Australia, Sydney, NSW, Australia) were placed on the chest in the right mid-clavicular line at the eighth intercostal space and on the rib below at the costal margin to record EMG signals from the lateral chest wall overlying the costal diaphragm. The EMG signals were recorded using Profusion Sleep v.3 software (Compumedics), with a sampling rate of 256 Hz, amplitude range of 2 mV, and a bandpass filter of 20-100 Hz, in accordance with settings recommended by the American Academy of Sleep Medicine (AASM) (Iber et al, 2007;Penzel et al, 2007)…”
Section: Recording and Analysis Of Semgcwmentioning
confidence: 99%
“…Briefly, surface electrodes (3M Red dot; 3M Australia, Sydney, NSW, Australia) were placed on the chest in the right mid-clavicular line at the eighth intercostal space and on the rib below at the costal margin to record EMG signals from the lateral chest wall overlying the costal diaphragm. The EMG signals were recorded using Profusion Sleep v.3 software (Compumedics), with a sampling rate of 256 Hz, amplitude range of 2 mV, and a bandpass filter of 20-100 Hz, in accordance with settings recommended by the American Academy of Sleep Medicine (AASM) (Iber et al, 2007;Penzel et al, 2007)…”
Section: Recording and Analysis Of Semgcwmentioning
confidence: 99%
“…For example, the algorithm developed for a nocturnal sleep pattern may not suitable for non-nocturnal sleep. Penzel et al provided an in depth review of some of these approaches in clinical settings, offering a quantitative analysis of their performance and requirements 106 . Palotti et al evaluated the performance of some of the most common approaches, including statistical ML, on actigraphy data 107 .…”
Section: Conventional Sleep Classification Methodsmentioning
confidence: 99%
“…Mit Piezosensoren ausgestattete ö sophageale Druckkatheter sind d ü nn und f ü r den Patienten relativ wenig beeintr ä chtigend. Bei der digitalen Polysomnografi e werden die Atmungssignale minimal mit 25 Hz und optimal mit 100 Hz digitalisiert [13]. Die pulsoximetrisch gemessene Sauerstoffs ä ttigung am Finger oder besser am Ohr ist ein Standardparameter der kardiorespiratorischen Polysomnografi e. Die Pulsoximetrie liefert neben der Sauerstoffs ä ttigung auch die Pulsfrequenz.…”
Section: Schlaf Und Bewegungunclassified
“…Langzeit-EKG Systeme verf ü gen auch ü ber die zur Auswertung erforderliche validierte Software. Das EKG wird minimal mit 200 Hz und optimal mit 500 Hz digitalisiert [13]. Eine Aufzeichnung des arteriellen Blutdrucks ist zum Nachweis n ä chtlicher arterieller Hypertonie und deren gezielter Behandlung besonders sinnvoll.…”
Section: Herz-und Kreislauffunktionunclassified
See 1 more Smart Citation