Digital Workflow for Full‐Arch Immediate Implant Placement Using a Stackable Surgical Guide Fabricated Using SLM Technology

Abstract: The failing dentition of partially edentulous individuals may be used as an initial reference for stackable restrictive surgical guides during full‐arch immediate implant placement. The stackable guide option derived from a digital workflow increases the predictability of the performance of bone reduction, immediate implant placement, and immediate loading of provisional implant‐supported fixed dental prostheses. The present paper aims to report a practical approach to design and produce a metal framework with… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
36
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 31 publications
(36 citation statements)
references
References 23 publications
0
36
0
Order By: Relevance
“…In general, surgical guides are easily adaptable to various clinical scenarios when they are properly supported. It has been shown that natural dentition and existing fixed dental prostheses provide support and stability to the guide during implant insertion [14]. The present study suggests the use of endosseus screws for that purpose.…”
Section: Discussionmentioning
confidence: 60%
See 2 more Smart Citations
“…In general, surgical guides are easily adaptable to various clinical scenarios when they are properly supported. It has been shown that natural dentition and existing fixed dental prostheses provide support and stability to the guide during implant insertion [14]. The present study suggests the use of endosseus screws for that purpose.…”
Section: Discussionmentioning
confidence: 60%
“…Although the chair time can be reduced by following the described technical protocol [2,13,14], it is necessary perform two scans instead of one [2]. Different from previous techniques, during the second scan, the surgical guide scanning device is indicated to be retained by endosseous screws that will guarantee a fixed retention, instead of just being muco-supported.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, Ponnusamy et al have found that the same material, when printed using different machines, produced different mechanical and microscopic properties for many reasons. Therefore, the repetition of the mechanical performance of printed parts using different machines requires further research and comparison [ 80 ].…”
Section: Bioceramic 3d Printing Overviewmentioning
confidence: 99%
“…The mandibular posterior region may present four branching patterns of the inferior alveolar canal (IAC) branches [ 10 ]. Consequently, familiarity of the patient’s anatomical structures and variations permit the dental clinician propose an adequate treatment plan [ 10 – 12 ].…”
Section: Introductionmentioning
confidence: 99%