1983
DOI: 10.1016/0167-5087(83)91273-5
|View full text |Cite
|
Sign up to set email alerts
|

Direct analysis of 210Pb in sediment samples: Self-absorption corrections

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
221
0
10

Year Published

1994
1994
2017
2017

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 605 publications
(231 citation statements)
references
References 3 publications
0
221
0
10
Order By: Relevance
“…Because gamma analysis detects lattice bound Zl°pb that may resist acid leaching, incomplete extraction is a possible source of negative error in 21°pb concentrations determined by alpha counting. However, Cutshall et al (1983) report no systematic differences between 21°pb concentrations determined by gamma and alpha spectroscopy for sediment samples having 21°Pb concentrations comparable to those encountered in this study (~<22 dpm g-l). Furthermore, agreement between 21°pb activities of replicate samples digested with concentrated or dilute acid (Fig.…”
Section: Comparison Of Gamma and Alpha Spectroscopymentioning
confidence: 61%
See 1 more Smart Citation
“…Because gamma analysis detects lattice bound Zl°pb that may resist acid leaching, incomplete extraction is a possible source of negative error in 21°pb concentrations determined by alpha counting. However, Cutshall et al (1983) report no systematic differences between 21°pb concentrations determined by gamma and alpha spectroscopy for sediment samples having 21°Pb concentrations comparable to those encountered in this study (~<22 dpm g-l). Furthermore, agreement between 21°pb activities of replicate samples digested with concentrated or dilute acid (Fig.…”
Section: Comparison Of Gamma and Alpha Spectroscopymentioning
confidence: 61%
“…The detector was calibrated using synthetic standards made by diluting Standard Pitchblende Ore (US EPA, Las Vegas) with 99.5% SiO 2 to produce a range of sample geometries. 2~°pb activities were corrected for selfattenuation following the procedure of Cutshall et al (1983). Background corrections for Zl°Pb were determined by counting empty aluminum cans.…”
Section: X-radiographymentioning
confidence: 99%
“…These measurements were done for 2 min. 21 Each sample contained a self-absorption factor that was incorporated in the final tally of the total 210 Pb. Samples were then dried at 60 o C until a constant weight was reached.…”
Section: Methodsmentioning
confidence: 99%
“…This sieved material was also used for radioisotope activity and metal concentration determinations. Activities of 2•øpb (t•/2 = 22.3 years) were determined either by alpha [Flynn, 1968] or gamma [Cutshall et al, 1983] spectroscopy.…”
Section: Laboratory Methodsmentioning
confidence: 99%