2014
DOI: 10.1194/jlr.d046128
|View full text |Cite
|
Sign up to set email alerts
|

Direct analysis of sialylated or sulfated glycosphingolipids and other polar and neutral lipids using TLC-MS interfaces

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
21
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 35 publications
(22 citation statements)
references
References 47 publications
1
21
0
Order By: Relevance
“…It is worth mentioning that sialylation is also an important feature of glycolipids such as gangliosides, [43][44][45][46] lipooligosaccharides (LOS) and lipopolysaccharides (LPS). [47][48][49] Further improvement in ganglioside analysis includes negative-ion electrospray ionization (ESI)-MS, [50][51][52][53][54][55][56] matrix-assisted laser desorption/ionization (MALDI)-MS, [57][58][59] MS imaging, [60][61][62][63][64] and ion mobility (IM)-MS. 65 This section summarizes MS methods as well as their limitations in the profiling of intact sialoglycoproteins.…”
Section: Glycoproteinsmentioning
confidence: 99%
“…It is worth mentioning that sialylation is also an important feature of glycolipids such as gangliosides, [43][44][45][46] lipooligosaccharides (LOS) and lipopolysaccharides (LPS). [47][48][49] Further improvement in ganglioside analysis includes negative-ion electrospray ionization (ESI)-MS, [50][51][52][53][54][55][56] matrix-assisted laser desorption/ionization (MALDI)-MS, [57][58][59] MS imaging, [60][61][62][63][64] and ion mobility (IM)-MS. 65 This section summarizes MS methods as well as their limitations in the profiling of intact sialoglycoproteins.…”
Section: Glycoproteinsmentioning
confidence: 99%
“…From the technical point of view, of high interest is the work of Park et al . who recently developed two innovative TLC MS interfaces for glycolipids CAMAG TLC and liquid extraction surface analysis (LESA™) TLC. Both systems were coupled with an ESI QSTAR Pulsar i QTOF MS and compared in terms of sensitivity, analysis time and potential features for bovine brain total lipid extract analysis .…”
Section: Ms Hyphenation With Tlc and Ims For Glycolipidsmentioning
confidence: 99%
“…What seems to be the most promising recent develop ment of TLC MS interfacing in the field of gangliosides was achieved by coupling commercially available liquid extraction surface automated devices to an electrospray ionization MS source [57]. Indeed, the two surface extrac tion systems, namely the TLC MS interface from CAMAG and the Liquid Extraction Surface Analysis (LESA®; CAMAG, Switzerland), showed reliable semi automated extraction abilities toward gangliosides that could be inject ed online into a Q q TOF MS spectrometer to be analyzed by MS and MS/MS.…”
Section: Recent Progress In Mass Spectrometric Analysis Of Gslsmentioning
confidence: 99%