2020
DOI: 10.3390/s20247274
|View full text |Cite
|
Sign up to set email alerts
|

Direct and Label-Free Determination of Human Glycated Hemoglobin Levels Using Bacteriorhodopsin as the Biosensor Transducer

Abstract: Glycated hemoglobin (HbA1c) levels are an important index for the diagnosis and long-term control of diabetes. This study is the first to use a direct and label-free photoelectric biosensor to determine HbA1c using bacteriorhodopsin-embedded purple membranes (PM) as a transducer. A biotinylated PM (b-PM) coated electrode that is layered with protein A-oriented antibodies against hemoglobin (Hb) readily captures non-glycated Hb (HbA0) and generates less photocurrent. The spectra of bacteriorhodopsin and Hb over… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(14 citation statements)
references
References 36 publications
1
13
0
Order By: Relevance
“…We note that the K D values found for our engineered GHA immobilized on the Type-1 and Type-2 surfaces are similar to those for gHb-targeted aptamer reported in other works. ,,, However, the K D value for our Type-3 surface, 0.32 nM, is substantially lower than many values reported in literature for gHb-targeted aptamers. Taken together and in the context of previous literature, our results support the assertion that the inclusion of 11MUA and DMOL surface modifications into aptamer-based SPR biosensing surfaces can improve the inherent specific affinities engineered into aptamers, through their aptamer enhancing and antifouling properties.…”
Section: Resultssupporting
confidence: 90%
“…We note that the K D values found for our engineered GHA immobilized on the Type-1 and Type-2 surfaces are similar to those for gHb-targeted aptamer reported in other works. ,,, However, the K D value for our Type-3 surface, 0.32 nM, is substantially lower than many values reported in literature for gHb-targeted aptamers. Taken together and in the context of previous literature, our results support the assertion that the inclusion of 11MUA and DMOL surface modifications into aptamer-based SPR biosensing surfaces can improve the inherent specific affinities engineered into aptamers, through their aptamer enhancing and antifouling properties.…”
Section: Resultssupporting
confidence: 90%
“…After binding with its receptor, BNP can effectively activate intracellular guanosine cyclase, synthesize cGMP to play biological effects, achieve antidiuretic, inhibit sympathetic nervous activity, reduce pulmonary circulation, inhibit the antirenin angiotensin system, reduce peripheral circulation vascular tension ability, and effectively dilate blood vessels [ 33 ]. BNP has a short half-life and is catabolized by neuronal peptidase.…”
Section: Discussionmentioning
confidence: 99%
“…Among the various transduction methods, electrochemical sensors are widely employed for analytical applications due to the simple operation, rapid response, cost-effectiveness, portability, and ease of fabrication [ 24 ]. Though there are several reports of HbA1c quantification using optical [ 25 ], photoacoustic [ 26 ], electrochemical piezoelectric [ 27 ], chemiluminescence [ 28 ], photoelectric [ 29 ], magnetic immunoassay [ 30 ], etc., majority of the reports have focused on electrochemical methods of transduction owing to their merits. This review focuses only on the progress in electrochemical strategies for HbA1c measurement.…”
Section: Sensors For Quantification Of Hba1cmentioning
confidence: 99%
“…The sensor performance was validated using 19 human blood samples and the results showed a good agreement with conventional measurements. The detection time of the sensor is 15 min [ 29 ]. Further fine-tuning of the fabrication parameters are required for reducing the response time to under a minute for applications as a point-of-care diagnostic device.…”
Section: Aptamer-based Sensors For Hba1c Detectionmentioning
confidence: 99%